Technical Data Sheet

Physical PropertiesTest ConditionTest MethodTest ResultUnit
Outdoor Suitability全部UL 746Cf1
Modeling ShrinkageAcross FlowISO 294-41.0%
Modeling Shrinkage流量ISO 294-40.35%
Moisture Absorption24 hr, 23°CISO 620.73%
Moisture AbsorptionSaturation, 23°CISO 624.3%
Moisture AbsorptionEquilibrium, 23°C, 50% RHISO 621.8%
1%重量损失 (TGA)NF F16-101I3
DensityISO 1183/A1.46g/cm³
Mechanical PropertiesTest ConditionTest MethodTest ResultUnit
Tensile StrengthBreak, 23°CASTM D638140Mpa
Tensile StrengthBreak, 23°CISO 527-2/1A150Mpa
Tensile Modulus23°CISO 527-2/1A10200Mpa
Tensile ElongationBreak, 23°CASTM D6383.0%
Tensile ElongationBreak, 23°CISO 527-22.3%
Flexural Modulus23°CASTM D790, ISO 17810000Mpa
Flexural Strength23°CASTM D790225Mpa
Flexural Strength23°CISO 178255Mpa
Thermal PropertiesTest ConditionTest MethodTest ResultUnit
Deflection Temperature Under Load?1.8 MPa, UnannealedISO 75-2/Af245°C
Melting temperatureISO 11357-3263°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Dielectric Strength0.800 mmIEC 60243-138KV/mm
Comparative Tracking IndexSolution AIEC 60112600V
Volume ResistivityIEC 600936.0E+14ohms·cm
InjectionTest ConditionTest MethodTest ResultUnit
Drying Temperature80°C
Suggested Max Moisture0.20%
Mold Temperature60 到 90°C
Rear Temperature265 到 275°C
Middle Temperature265 到 275°C
Front Temperature270 到 280°C
Impact PropertiesTest ConditionTest MethodTest ResultUnit
Charpy Notched Impact Strength-30°CISO 179/1eA9.5kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA10kJ/m²
Notched Izod Impact Strength23°CASTM D25685J/m
Charpy Unnotched Impact Strength-30°CISO 179/1eU60kJ/m²
Charpy Unnotched Impact Strength23°CISO 179/1eU60kJ/m²
FlammabilityTest ConditionTest MethodTest ResultUnit
Glow Wire Flammability Index0.8 mmIEC 60695-2-12960°C
Glow Wire Flammability Index1.6 mmIEC 60695-2-12960°C
Glow Wire Flammability Index3.2 mmIEC 60695-2-12960°C
Oxygen IndexISO 4589-233%
Glow Wire Ignition Temperature0.8 mmIEC 60695-2-13775°C
European Railways CertificationsR22EN 45545-2HL3
European Railways CertificationsR23EN 45545-2HL3
Flame Rating0.8 mmUL 94V-0
Flame Rating1.6 mmUL 94V-0 5VA
Flame Rating3.2 mmUL 94V-0 5VA
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.