Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Outdoor Suitability | 全部 | UL 746C | f1 | |
Modeling Shrinkage | Across Flow | ISO 294-4 | 1.0 | % |
Modeling Shrinkage | 流量 | ISO 294-4 | 0.35 | % |
Moisture Absorption | 24 hr, 23°C | ISO 62 | 0.73 | % |
Moisture Absorption | Saturation, 23°C | ISO 62 | 4.3 | % |
Moisture Absorption | Equilibrium, 23°C, 50% RH | ISO 62 | 1.8 | % |
1%重量损失 (TGA) | | NF F16-101 | I3 | |
Density | | ISO 1183/A | 1.46 | g/cm³ |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Strength | Break, 23°C | ASTM D638 | 140 | Mpa |
Tensile Strength | Break, 23°C | ISO 527-2/1A | 150 | Mpa |
Tensile Modulus | 23°C | ISO 527-2/1A | 10200 | Mpa |
Tensile Elongation | Break, 23°C | ASTM D638 | 3.0 | % |
Tensile Elongation | Break, 23°C | ISO 527-2 | 2.3 | % |
Flexural Modulus | 23°C | ASTM D790, ISO 178 | 10000 | Mpa |
Flexural Strength | 23°C | ASTM D790 | 225 | Mpa |
Flexural Strength | 23°C | ISO 178 | 255 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | 1.8 MPa, Unannealed | ISO 75-2/Af | 245 | °C |
Melting temperature | | ISO 11357-3 | 263 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric Strength | 0.800 mm | IEC 60243-1 | 38 | KV/mm |
Comparative Tracking Index | Solution A | IEC 60112 | 600 | V |
Volume Resistivity | | IEC 60093 | 6.0E+14 | ohms·cm |
Injection | Test Condition | Test Method | Test Result | Unit |
---|
Drying Temperature | | | 80 | °C |
Suggested Max Moisture | | | 0.20 | % |
Mold Temperature | | | 60 到 90 | °C |
Rear Temperature | | | 265 到 275 | °C |
Middle Temperature | | | 265 到 275 | °C |
Front Temperature | | | 270 到 280 | °C |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 9.5 | kJ/m² |
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 10 | kJ/m² |
Notched Izod Impact Strength | 23°C | ASTM D256 | 85 | J/m |
Charpy Unnotched Impact Strength | -30°C | ISO 179/1eU | 60 | kJ/m² |
Charpy Unnotched Impact Strength | 23°C | ISO 179/1eU | 60 | kJ/m² |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Glow Wire Flammability Index | 0.8 mm | IEC 60695-2-12 | 960 | °C |
Glow Wire Flammability Index | 1.6 mm | IEC 60695-2-12 | 960 | °C |
Glow Wire Flammability Index | 3.2 mm | IEC 60695-2-12 | 960 | °C |
Oxygen Index | | ISO 4589-2 | 33 | % |
Glow Wire Ignition Temperature | 0.8 mm | IEC 60695-2-13 | 775 | °C |
European Railways Certifications | R22 | EN 45545-2 | HL3 | |
European Railways Certifications | R23 | EN 45545-2 | HL3 | |
Flame Rating | 0.8 mm | UL 94 | V-0 | |
Flame Rating | 1.6 mm | UL 94 | V-0 5VA | |
Flame Rating | 3.2 mm | UL 94 | V-0 5VA | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.