Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 23°C,24hr | ISO62 | 1.1 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Modulus | 23°C | ISO527-2/1A | 3500 | Mpa |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Surface Resistivity | | IEC60093 | 1E+15 | ohms |
Volume Resistivity | | IEC60093 | 1E+15 | ohms·cm |
Dissipation Factor? | | IEC60250 | 0.020 | |
Dielectric Strength | 2.00mm | IEC60243-1 | 34 | KV/mm |
Relative Permittivity | | IEC60250 | 3.50 | |
Comparative Tracking Index | SolutionA | IEC60112 | 600 | V |
Comparative Tracking Index | SolutionB | IEC60112 | 475 | V |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 0.40mm | UL94 | V-0 | |
Glow Wire Flammability Index | 0.8mm | IEC60695-2-12 | 960 | °C |
Glow Wire Flammability Index | 1.6mm | IEC60695-2-12 | 960 | °C |
Glow Wire Flammability Index | 3.2mm | IEC60695-2-12 | 960 | °C |
Oxygen Index | | ISO4589-2 | 36 | % |
Glow Wire Ignition Temperature | 0.8mm | IEC60695-2-13 | 700 | °C |
Glow Wire Ignition Temperature | 1.6mm | IEC60695-2-13 | 700 | °C |
Glow Wire Ignition Temperature | 3.2mm | IEC60695-2-13 | 700 | °C |
FrenchFireIndex | | NFF16-101 | F2 | |
FrenchSmokeIndex | | NFF16-101 | I2 | |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|
EuropeanRailwaysCertifications | R23 | EN45545-2 | HL3 | |
EuropeanRailwaysCertifications | R25 | EN45545-2 | HL3 | |
EuropeanRailwaysCertifications | R22 | EN45545-2 | HL3 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.