Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 24 hr | ASTM D570 | 0.12 | % |
Melt Mass-Flow Rate | 230°C/3.8 kg | ISO 1133 | 8.0 | g/10 min |
Modeling Shrinkage - Flow | | ASTM D955 | 0.20 到 0.60 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Modulus | | ISO 527-2/1 | 3100 | Mpa |
Tensile Stress | Break | ISO 527-2/5 | 62.0 | Mpa |
Tensile Strain | Break | ISO 527-2/5 | 3.0 | % |
Flexural Modulus | | ISO 178 | 3100 | Mpa |
Flexural Stress | | ISO 178 | 100 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Vicat Softening Temperature | | ISO 306/B50 | 95.0 | °C |
Deflection Temperature Under Load? | 1.8 MPa, Unannealed | ISO 75-2/A | 90.0 | °C |
Coefficient of Linear Thermal Expansion (Flow) | | ASTM D696 | 6.0E-5 | cm/cm/°C |
Injection | Test Condition | Test Method | Test Result | Unit |
---|
Rear Temperature | | | 210 到 240 | °C |
Middle Temperature | | | 210 到 240 | °C |
Front Temperature | | | 210 到 240 | °C |
Drying Temperature | | | < 80 | °C |
Drying time - Hot air dryer | | | 3.0 到 4.0 | hr |
Processing (Melt) Temp | | | 210 到 240 | °C |
Mold Temperature | | | 50 到 70 | °C |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | M -Sale | ISO 2039-2 | 75 | |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|
Refractive index of light | | ISO 489 | 1.550 | |
Transmittance | 3200 µm | ISO 13468-1 | 91.0 | % |
Transmittance | 150000 µm 4 | ISO 13468-1 | 82.0 | % |
Haze | 3200 µm | ISO 14782 | < 0.50 | % |
Haze | 150000 µm 4 | ISO 14782 | 6.5 | % |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Flammability level | 1.5 mm | IEC 60695-11-10, -20 | HB | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.