Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Melt Volume flow Rate | 260℃,5 kg 260℃/5.0 kg | ISO 1133 | 30 | cm3/10min |
Density | | ISO 1183 | 1.55 | g/cm³ |
Apparent Density | | ISO 60 | 0.8 | g/cm³ |
Moisture Absorption | Saturation,23℃ Saturation,23℃ | ISO 62 | 0.3 | % |
Moisture Absorption | Equilibrium,23℃,50% RH Equilibrium,23℃,50% RH | ISO 62 | 0.1 | % |
Modeling Shrinkage | TD:270℃,2.0 mm Across Flow : 518°F, 0.0787 in 2 2 | ISO 294-4 | 0.9 | % |
Modeling Shrinkage | TD:120℃,2.0 mm,2 hrs Across Flow : 120°C, 2 hr, 2.00 mm 3 3 | ISO 294-4 | 0.2 | % |
Modeling Shrinkage | MD:270℃,2.0 mm Flow : 518°F, 0.0787 in 2 2 | ISO 294-4 | 0.3 | % |
Modeling Shrinkage | MD:120℃,2.0 mm,2 hrs Flow : 120°C, 2 hr, 2.00 mm 3 3 | ISO 294-4 | 0.1 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Flexural Strength | 23℃ 23℃ 4 | ISO 178 | 230 | Mpa |
Tensile Strength | Break,23℃ Break,23℃ | ISO 527-2/5 | 145 | Mpa |
Tensile Modulus | 23℃ 23℃ | ISO 527-1-2 | 10400 | Mpa |
Flexural Modulus | 23℃ 23℃ 4 | ISO 178-A | 10300 | Mpa |
Flexural Strain | | | 3 | % |
Tensile Strain | Break,23℃ Break,23℃ | ISO 527-2/5 | 2.8 | % |
Electrical | Test Condition | Test Method | Test Result | Unit |
---|
Comparative Tracking Index | Solution A Solution A | IEC 60112 | 250 | V |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Notched Impact Strength | -30℃ -30°C | ISO 179/1eA | < 10 | kJ/m² |
Charpy Notched Impact Strength | 23℃ 23°C | ISO 179/1eA | < 10 | kJ/m² |
Notched Izod Impact Strength | -30℃ -30°C | ISO 180-1A | < 10 | kJ/m² |
Notched Izod Impact Strength | 23℃ 23°C | ISO 180-1A | < 10 | kJ/m² |
Unnotched Izod Impact Strength | -30℃ -30°C | ISO 180/1U | 55 | kJ/m² |
Unnotched Izod Impact Strength | 23℃ 23°C | ISO 180/1U | 55 | kJ/m² |
Charpy Unnotched Impact Strength | -30℃ -30°C | ISO 179/1eU | 55 | kJ/m² |
Charpy Unnotched Impact Strength | 23℃ 23°C | ISO 179/1eU | 65 | kJ/m² |
Thermal | Test Condition | Test Method | Test Result | Unit |
---|
Vicat Softening Temperature | B120 B120 | ISO 306/B120 | 205 | °C |
Melting Temperature | | ISO 11357-3 | 225 to 250 | °C |
Coefficient of Linear Thermal Expansion | TD:23~55℃ TD:23 to 55℃ | ISO 11359-2 | 0.000090 | 1/℃ |
Coefficient of Linear Thermal Expansion | MD:23~55℃ MD:23 to 55℃ | ISO 11359-2 | 0.000030 | 1/℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.