PCTG Tritan™ FX100 EASTMAN USA
105
- Unit Price:
- $4185 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 66.8MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515
serv********
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:Chemical resistance Hydrolysis resistance
- Application Areas:Electrical applications Household daily necessiti
- Color:--
- Grade:Injection grade
Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Moisture Absorption | 23°C,24hr,0.250mm | ASTMD570 | 0.50 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Change in Haze | 23°C | ASTMD1044 | 23haze | % |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Linear thermal expansion coefficient | MD:23°C,0.250mm | ASTMD696 | 9E-05 | cm/cm/°C |
Melting temperature | 110 | °C | ||
Specific Heat | 60°C | DSC | 1700 | J/kg/°C |
100°C | DSC | 1900 | J/kg/°C | |
150°C | DSC | 2200 | J/kg/°C | |
200°C | DSC | 2400 | J/kg/°C | |
250°C | DSC | 2600 | J/kg/°C |
Film | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Film Puncture Energy | 250µm | ASTMD3763 | 4.60 | J |
Film Thickness - Tested) | 250 | µm | ||
Oxygen Transmission Rate | 23°C,250µm,50%RH | ASTMD3985 | 32 | cm³·mm/m²/atm/24hr |
Water Vapor Transmission Rate | 23°C,100%RH,250µm | ASTMF1249 | 4.0 | g/m²/24hr |
38°C,100%RH,250µm | ASTMF1249 | 11 | g/m²/24hr | |
Secant Modulus | MD:250µm | ASTMD882 | 1500 | Mpa |
TD:250µm | ASTMD882 | 1400 | Mpa | |
Tensile Elongation | MD:Yield,250μm | ASTMD882 | 7.0 | % |
TD:Yield,250μm | ASTMD882 | 7.0 | % | |
MD:Break,250μm | ASTMD882 | 180 | % | |
TD:Break | ASTMD882 | 200 | % | |
Tensile Strength | TD:Yield,250μm | ASTMD882 | 40.0 | Mpa |
MD:Break,250μm | ASTMD882 | 59.0 | Mpa | |
TD:Break,250μm | ASTMD882 | 52.0 | Mpa | |
MD:Yield,250μm | ASTMD882 | 41.0 | Mpa | |
Tearing Strength | TD:250µm | ISO6383-1 | 11.0 | N/mm |
MD:250µm | ISO6383-1 | 11.0 | N/mm | |
CarbonDioxidePermeability6 | 23°C,254.0µm | ASTMD1434 | 150 | cm³·mm/m²/atm/24hr |
ElmendorfTearStrength | MD:23°C,250.0µm | ASTMD1922 | 5 | N |
TD:23°C,250.0µm | 6 | N | ||
PPTTearResistance | MD:23°C,250.0µm | - | 42 | N |
TD:23°C,250.0µm | - | 56 | N | |
Tearing Strength | MD:23°C,250.0µm | ASTMD1938 | 410 | gf |
TD:23°C,250.0µm | ASTMD1938 | 310 | gf | |
Gardner Impact | -30°C,250µm | ASTMD1709A | 910 | g |
23°C,250µm | ASTMD1709A | 880 | g |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
The Yellow Index | 250mm | ASTMD1925 | 0.50 | YI |
UVTransmittance10 | 250.0µm | 89 | % | |
Refractive index of light | ASTMD542 | 1.550 | ||
Gloss | 60°,250µm | ASTMD2457 | 161 | |
Transmittance | 250µm | ASTMD1003 | 92.0 | % |
Haze | 250µm | ASTMD1003 | 0.70 | % |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
SurfaceEnergy | Dispersive:23°C,250.0µm | ASTMD5946 | 39 | dyne/cm |
Polar:23°C,250mm | ASTMD5946 | 8 | dyne/cm | |
Total:23°C,250.0µm | ASTMD5946 | 46 | dyne/cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.