Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | trans,dry | ISO 294 | 0.85 | % |
Modeling Shrinkage | long,dry | ISO 294 | 0.70 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Impact Strength | Charpy,-30℃,dry(cond) | ISO 179/1eU | 20(25) | KJ/m |
Impact Strength | Charpy,23℃,dry(cond) | ISO 179/1eU | 50(50) | KJ/m |
Tensile Elongation?(Break) | 5mm/min,dry(cond) | ISO 527 | 1.5(1.5) | % |
hardness | dry(cond) | ISO 2039-1 | 260(260) | Mpa |
Notched Impact Strength | Charpy,23℃,dry(cond) | ISO 179/1eA | 5(5) | KJ/m |
Notched Impact Strength | Charpy,-30℃,dry(cond) | ISO 179/1eA | 3(4) | KJ/m |
Tensile Strength(Break) | 5mm/min,dry(cond) | ISO 527 | 105(105) | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Continuous Use Temperature | short term,dry | ISO 2578 | 250 | °C |
Continuous Use Temperature | long term,dry | ISO 2578 | 140 | °C |
Flame retardancy | 0.8mm | ISO 1210 | HB | rating |
Deflection Temperature Under Load? | 0.45MPa,dry | ISO 75 | 255 | °C |
Deflection Temperature Under Load? | 1.80MPa,dry | ISO 75 | 145 | °C |
Deflection Temperature Under Load? | 8.00MPa,dry | ISO 75 | 115 | °C |
Melting Temperature | dry | ISO 11357 | 325 | °C |
Coefficient of Linear Thermal Expansion | 23-55℃,dry | ISO 11359 | 0.5 | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric Strength | dry(cond) | IEC 60243-1 | 32(32) | KV/mm |
Surface Resistivity | cond | IEC 60093 | 10 | Ω |
Volume Resistivity | dry(cond) | IEC 60093 | 10 | Ω.cm |
Arc Resistance | cond | IEC 60112 | 575 | V |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Density | dry | ISO 1183 | 1.55 | g/cm |
Moisture Absorption | 23℃/sat | ISO 62 | 3.5 | % |
Hygroscopicity | 23℃/50%rh | ISO 62 | 1.5 | % |
Other performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Modulus | 1mm/min,dry(cond) | ISO 527 | 7500(7500) | Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.