PEEK VICTREX® 450GL20 VICTREX UK
178
- Unit Price:
- $85215 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 50MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:high strength Glass fiber reinforced
- Application Areas:Non specific food Nursing supplies Medical supplies
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Density/specific gravity 3 | ISO1183 | 1.43 | g/cm³ | |
SpiralFlow4.5 | 内部方法 | 10.0 | CM | |
Shrinkage rate 6 | TD | ISO294-4 | 0.90 | % |
MD | ISO294-4 | 0.30 | % | |
Water absorption rate | Saturation,23°C | ISO62 | 0.40 | % |
Water absorption rate - saturation | 100°C | ISO62 | 0.45 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile modulus | 23°C | ISO527-2 | 8800 | Mpa |
Tensile stress | Break,23°C | ISO527-2 | 160 | Mpa |
Tensile strain | Break,23°C | ISO527-2 | 3.4 | % |
Bending modulus | 23°C | ISO178 | 8300 | Mpa |
Bending stress | 23°C | ISO178 | 250 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Hot deformation temperature | 1.8MPa,Unannealed | ISO75-2/Af | 315 | °C |
Glass transition temperature | --7 | ISO11357-2 | 143 | °C |
--8 | ISO11357-2 | 150 | °C | |
Melting temperature | ISO11357-3 | 343 | °C | |
Linear coefficient of thermal expansion | MD:<143°C | ISO11359-2 | 2E-05 | cm/cm/°C |
MD:>143°C | ISO11359-2 | 2.2E-05 | cm/cm/°C | |
TD:<143°C | ISO11359-2 | 4.5E-05 | cm/cm/°C | |
TD:>143°C | ISO11359-2 | 1.2E-04 | cm/cm/°C | |
thermal conductivity | 23°C9 | ISO22007-4 | 0.30 | W/m/K |
23°C10 | ISO22007-4 | 0.35 | W/m/K |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Volume resistivity | IEC60093 | 1E+16 | ohms·cm | |
Dielectric strength | 2.00mm | IEC60243-1 | 24 | KV/mm |
Dielectric constant | 23°C,1kHz | IEC60250 | 3.10 | |
Dissipation factor | 23°C,1MHz | IEC60250 | 5E-03 | |
Leakage Trace Index | IEC60112 | 150 | V |
Filling analysis | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Melt viscosity | 400°C | ISO11443 | 475 | Pa·s |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Impact strength of cantilever beam gap | 23°C | ISO180/A | 10 | kJ/m² |
Unscented Izod impact strength | 23°C | ISO180 | 65 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Shore hardness | Shore D,23°C | ISO868 | 86 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.