Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | MD Flow | ISO 294-4 | 0.2 | % |
Moisture Absorption | Saturation,23℃,2.00 mm Saturation,23℃,2.00 mm | ISO 62 | 0.6 | % |
Moisture Absorption | Equilibrium,23℃,50% RH,2.00 mm | ISO 62 | 0.15 | % |
Modeling Shrinkage | TD Across Flow | ISO 294-4 | 0.9 | % |
Ejection Temperature | | | 170 | °C |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Strength | Break | ISO 527-2 | 162 | Mpa |
Tensile Modulus | | ISO 527-2 | 13500 | Mpa |
Tensile Strain | Break | ISO 527-2 | 2.3 | % |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Notched Impact Strength | 23℃ 23℃ | ISO 179/1eA | 8.8 | kJ/m² |
Charpy Unnotched Impact Strength | 23℃ 23℃ | ISO 179/1eU | 60 | kJ/m² |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Burning Rate | 1 mm 1.00 mm 3 | ISO 3795 | < 100 | mm/min |
Flame Rating | 1.50 mm 1.5 mm | UL 94 | HB | |
Flame Rating | 3.00 mm 3.0 mm | UL 94 | HB | |
Flame Rating | 1.5 mm 1.5 mm | IEC 60695-11-10, -20 | HB | |
Flame Rating | 3.0 mm 3.0 mm | IEC 60695-11-10, -20 | HB | |
FMVSS Flammability | | FMVSS 302 | B | |
Thermal | Test Condition | Test Method | Test Result | Unit |
---|
Melting Temperature | | ISO 11357-3 | 249 | °C |
Coefficient of Linear Thermal Expansion | TD | ISO 11359-2 | 0.000075 | 1/℃ |
Coefficient of Linear Thermal Expansion | MD | ISO 11359-2 | 0.000017 | 1/℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.