Technical Data Sheet
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Elongation?(Break) | | ASTM D412/ISO 527 | 70 | % |
Tensile Modulus | | ASTM D412/ISO 527 | 2800 | kg/cm²(MPa)[Lb/in²] |
Tensile Modulus | | MPa | ISO 527-2 | 2800 |
Tensile Strength | | ASTM D638/ISO 527 | 81 | kg/cm²(MPa)[Lb/in²] |
Rockwell Hardness | | ASTM D785 | 107 | |
Flexural Modulus | | ASTM D790/ISO 178 | 3000 | kg/cm²(MPa)[Lb/in²] |
Charpy Unnotched Impact Strength | 23°C | | ISO 179/1eU | No Break |
Tensile Stress | Yield | MPa | ISO 527-2 | 80.0 |
Tensile Strain | Yield | % | ISO 527-2 | 4.0 |
Charpy Notched Impact Strength | 23°C | kJ/m² | ISO 179/1eA | 3.0 |
Charpy Notched Impact Strength | 23°C | kJ/m² | ISO 179/1eA | |
Tensile Strain (Break) | | % | ISO 527-2 | |
Tensile Strain (Break) | | % | ISO 527-2 | |
Charpy impact strength | | ASTM D256/ISO 179 | 3 | kg·cm/cm(J/M)ft·lb/in |
Charpy impact strength | | ASTM D256/ISO 179 | 不断 | kg·cm/cm(J/M)ft·lb/in |
Izod notch impact strength | | ASTM D256/ISO 179 | 20 | kg·cm/cm(J/M)ft·lb/in |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Coefficient of Linear Thermal Expansion | Flow | cm/cm/°C | ISO 11359-2 | 0.000070 |
Coefficient of Linear Thermal Expansion | Transverse | cm/cm/°C | ISO 11359-2 | 0.000070 |
Melting temperature | | °C | ISO 11357-3 | 255 |
Deflection Temperature Under Load? | 0.45 MPa | °C | ISO 75-2 | 115 |
Deflection Temperature Under Load? | 1.8 MPa,Unannealed | °C | ISO 75-2/A | 80.0 |
Deflection Temperature Under Load? | 1.8 MPa | °C | ISO 75-2 | 80.0 |
Deflection Temperature Under Load? | 0.45 MPa,Unannealed | °C | ISO 75-2/B | 115 |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Surface Resistivity | | ohms | IEC 60093 | |
Volume Resistivity | | ohm·cm | IEC 60093 | |
Volume Resistivity | | ohm·cm | IEC 60093 | |
Dissipation Factor? | 100HZ | | IEC 60250 | |
Dissipation Factor? | 1E+6HZ | | IEC 60250 | 0.0021 |
Dissipation Factor? | 1MHZ | | IEC 60250 | 0.0021 |
Relative Permittivity | 100HZ | | IEC 60250 | |
Relative Permittivity | 1E+6HZ | | IEC 60250 | 3.20 |
Relative Permittivity | 1MHZ | | IEC 60250 | 3.20 |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Density | | g/cm³ | ISO 1183 | |
Density | | kg/m³ | ISO 1183 | 1370 |
Modeling Shrinkage | Flow | % | ISO 2577 | 1.8 |
Modeling Shrinkage | Across Flow | % | ISO 2577 | 2.0 |
Moisture Absorption | Saturation, 23°C | % | ISO 62 | 0.50 |
Moisture Absorption | Saturation | % | ISO 62 | 0.50 |
Moisture Absorption | Equilibrium, 23°C, 50% RH | % | ISO 62 | 0.20 |
Moisture Absorption | Equilibrium | % | ISO 62 | 0.20 |
Other performance | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | 0.750 mm | | IEC 60695-11-10, -20 | HB |
Flame Rating | 1.50 mm | | IEC 60695-11-10, -20 | HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.