PA46 Stanyl®  TW200B6 BK DSM JAPAN

156
  • Unit Price:
    $9116 USD/MT
  • Packaging Specification:
    25 KG/PKG
  • Supply Quantity:
    10MT
  • Delivery Terms:
    FOB
  • Port of Loading:
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 2787 3515View
serv********View

For more detailed information including pricing, customization, and shipping, please contact supplier.

Material Description
Technical Data Sheet

Material Description

  • Material Properties:Flame retardant
  • Application Areas:Electronic and electrical Automotive Applications
  • Color:--
  • Grade:Flame retardant enhanced grade

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
densityISO 11831.28g/cm³
Shrinkage rateAcross FlowISO 294-40.90%
Shrinkage rate流量ISO 294-40.20%
Water absorption rateEquilibrium, 23°C, 50% RHISO 622.6%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile modulus--ISO 527-224000Mpa
Tensile modulus120°CISO 527-210000Mpa
Tensile modulus160°CISO 527-28800Mpa
Tensile modulus180°CISO 527-28300Mpa
Tensile stressBreakISO 527-2240Mpa
Tensile stressBreak, 120°CISO 527-2125Mpa
Tensile stressBreak, 160°CISO 527-2105Mpa
Tensile stressBreak, 180°CISO 527-295.0Mpa
Tensile strainBreakISO 527-22.0%
Tensile strainBreak, 120°CISO 527-23.0%
Tensile strainBreak, 160°CISO 527-23.0%
Tensile strainBreak, 180°CISO 527-23.0%
Bending modulusISO 17818500Mpa
Thermal performanceTest ConditionTest MethodTest ResultUnit
Hot deformation temperature1.8 MPa, UnannealedISO 75-2/A290°C
Melting temperature 2ISO 11357-3295°C
Linear coefficient of thermal expansionFlowISO 11359-28.0E-6cm/cm/°C
Linear coefficient of thermal expansionAcross FlowISO 11359-23.4E-5cm/cm/°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Volume resistivityIEC 600931.0E+2ohms·cm
Impact performanceTest ConditionTest MethodTest ResultUnit
Charpy Notched Impact Strength -30°CISO 179/1eA6.5kJ/m²
Charpy Notched Impact Strength 23°CISO 179/1eA8.0kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU50kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU60kJ/m²
Impact strength of cantilever beam gap-40°CISO 180/1A6.5kJ/m²
Impact strength of cantilever beam gap23°CISO 180/1A8.0kJ/m²
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.