Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | Flow | ASTM D-955 | 0.8-2.0 | % |
Modeling Shrinkage | Across Flow | ASTM D-955 | 0.8-2.0 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Elongation | | ASTM D-638 | 40 | % |
Rockwell Hardness | | ASTM D-785 | 118 | R |
Flexural Modulus | | ASTM D-790 | 25000 | kg/cm2 |
Flexural Strength | | ASTM D-790 | 850 | kg/cm2 |
Tensile Strength | | ASTM D-638 | 550 | kg/cm2 |
Notched Impact Strength | 1/8",23℃ | ASTM D-256 | 4 | kg.cm/cm |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Flame resistance | | UL 94 | HB | |
Deflection Temperature Under Load? | | ASTM D-648 | 65 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric Constant | | ASTM D-150 | 3 | |
Dielectric Strength | | ASTM D-149 | 15 | KV/mm |
Volume Resistivity | | ASTM D-257 | 1.00×1016 | Ω.cm |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | | ASTM D-570 | 0.09 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.