Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | TD:3.00mm2 | 内部方法 | 1.0 | % |
Modeling Shrinkage | MD:3.00mm4 | 内部方法 | 0.40 | % |
Moisture Absorption | 23°C,24hr | ISO62 | 0.080 | % |
Moisture Absorption | 23℃, 24 hr | ISO 62 | 0.080 | % |
Modeling Shrinkage | TD: 3.00 mm | Internal Method | 1.0 | % |
Modeling Shrinkage | MD: 3.00 mm | Internal Method | 0.40 | % |
Flow Length 3 | 250℃, 1.00 mm | Internal Method | 7.00 | CM |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Modulus | 23℃ | ISO 527-2 | 8400 | Mpa |
Tensile Modulus | 23°C | ISO527-2 | 8400 | Mpa |
Flexural Modulus | 23°C | ISO178 | 7900 | Mpa |
Flexural Modulus | 23℃ | ISO 178 | 7900 | Mpa |
Flexural Strength | 23℃ | ISO 178 | 195 | Mpa |
Tensile Stress | Yield, 23℃ | ISO 527-2 | 125 | Mpa |
Tensile Stress | Yield,23°C | ISO527-2 | 125 | Mpa |
Tensile Strain | Break,23°C | ISO527-2 | 3.0 | % |
Tensile Strain | Break, 23℃ | ISO 527-2 | 3.0 | % |
Flexural Stress | 23°C | ISO178 | 195 | Mpa |
Charpy Notched Impact Strength | 23℃ | ISO 179 | 12 | kJ/m² |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | | UL 94 | HB | |
Coefficient of Linear Thermal Expansion (Flow) | -30 to 100℃ | ISO 11359-2 | 0.000042 | cm/cm/℃ |
Linear thermal expansion coefficient | MD:-30to100°C | ISO11359-2 | 4.2E-05 | cm/cm/°C |
Deflection Temperature Under Load? | 1.8 MPa, Unannealed | ISO 75-2/A | 208 | °C |
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ISO75-2/A | 208 | °C |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | | UL94 | HB | |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|
BarFlowLength4 | 250°C,1.00mm | 内部方法 | 7.00 | CM |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.