Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | TD:3.00mm2 | 内部方法 | 1.2 | % |
Modeling Shrinkage | MD:3.00mm4 | 内部方法 | 0.50 | % |
Moisture Absorption | 23°C,24hr | ISO62 | 0.070 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Stress | Yield,23°C | ISO527-2 | 110 | Mpa |
Tensile Strain | Break,23°C | ISO527-2 | 2.5 | % |
Tensile Modulus | 23°C | ISO527-2 | 6900 | Mpa |
Flexural Modulus | 23°C | ISO178 | 6500 | Mpa |
Coefficient of Friction (vs.Metal) | | SuzukiMethod | 0.15 | |
Flexural Stress | 23°C | ISO178 | 170 | Mpa |
Coefficient of Friction | | | 0.20 | |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | 0.45MPa,Unannealed | ISO75-2/B | 220 | °C |
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ISO75-2/A | 205 | °C |
Linear thermal expansion coefficient | MD:-30to100°C | ISO11359-2 | 5.3E-05 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Volume Resistivity | | IEC60093 | 5.6E+16 | ohms·cm |
Dielectric Strength | | IEC60243-1 | 14 | KV/mm |
Comparative Tracking Index | CTI | UL746 | PLC2 | |
Dissipation Factor | 23°C,50Hz | IEC60250 | 2E-03 | |
Dissipation Factor | 23°C,1MHz | IEC60250 | 0.020 | |
Arc Resistance | | IEC60950 | 135 | sec |
Dielectric Constant | 23°C,50Hz | IEC60250 | 3.60 | |
Dielectric Constant | 23°C,1kHz | IEC60250 | 3.80 | |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Unnotched Impact Strength | 23°C | ISO179 | 35 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | M-Sale,23°C | ISO2039-2 | 85 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 0.8mm | UL94 | V-0 | |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|
BarFlowLength8 | 250°C,1.00mm | 内部方法 | 140 | mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.