Material Description
Technical Data Sheet

Material Description

  • Material Properties:Flame retardant
  • Application Areas:Electrical field Electronic field Automotive sector
  • Color:--
  • Grade:Flame retardant grade

Technical Data Sheet

Physical propertiesTest ConditionTest MethodTest ResultUnit
densityASTM D792/ISO 11831.43
Water absorption rate 23 ℃/24hASTM D570/ISO 620.08%
physical property Test ConditionTest MethodTest ResultUnit
Under load4.6kg/cmASTM D-648165°C
Under load18.6kg/cmASTM D-64860°C
Coefficient of friction金属ASTM D-18940.14
Coefficient of friction本身ASTM D-18940.18
Taber wear amount1.000g·CS-17轮ASTM D-104413毫克/1.000m
Film plastic shrinkage80×80×3板材1.5-2.0%
Shrinkage rateTDISO294-42.0%
Water absorption rate(23°C,24hr)ISO620.080%
Shrinkage rateMDISO294-41.5%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
tensile strength 23℃ASTM D-638620kg/cm
bending strength 23℃ASTM D-790940kg/cm
Bending modulus23℃ASTM D-79028kg/cm
compressive strength23℃ASTM D-695930kg/cm
Fracture tensile elongation23℃ASTM D-63820%
Rockwell hardnessASTM D-785119
elongation at break ASTM D638/ISO 52720%
tensile strength ASTM D638/ISO 52765kg/cm²(MPa)[Lb/in²]
Rockwell hardnessASTM D785M86
Bending modulusASTM D790/ISO 1782800kg/cm²(MPa)[Lb/in²]
bending strength ASTM D790/ISO 17895kg/cm²(MPa)[Lb/in²]
tensile strength 23°CISO527-264.0Mpa
elongation at break 23°CISO527-28.0%
Tensile modulus23°CISO527-23000Mpa
bending strength 23°CISO178105Mpa
Bending modulus23°CISO1782900Mpa
Charpy Notched Impact Strength 23°CISO179/1eA2.5kJ/m²
Impact strength of simply supported beam without notch23°CISO179/1eU66kJ/m²
IZOD notch impact strengthASTM D256/ISO 17930kg·cm/cm(J/M)ft·lb/in
IZOD notch impact strengthASTM D256/ISO 17920kg·cm/cm(J/M)ft·lb/in
IZOD notch impact strengthASTM D256/ISO 17990kg·cm/cm(J/M)ft·lb/in
IZOD notch impact strengthASTM D256/ISO 17935kg·cm/cm(J/M)ft·lb/in
IZOD impact strengthUnnotched,23℃ASTM D-256120kg·cm/cm
IZOD impact strengthUnnotched,-40℃ASTM D-25650kg·cm/cm
IZOD impact strengthNotched,23℃ASTM D-2563.5kg·cm/cm
IZOD impact strengthNotched,-40℃ASTM D-2563.0kg·cm/cm
Thermal performanceTest ConditionTest MethodTest ResultUnit
Linear thermal expansionASTM D-6969.0cm/cm℃×10
Combustibility (rate)UL94V-0
Linear expansion coefficientASTM D696/ISO 113599.0x10^-5mm/mm.℃
Hot deformation temperature0.45MPaUnannealedISO75-2/Bf136°C
Hot deformation temperature1.80MPaAnnealedISO75-2/Af64.0°C
Coefficient of linear expansionMDISO11359-29E-05cm/cm/°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Volume resistanceIEC600932E+16Ω.cm
Insulation strengthIEC60243-126KV/mm
Dielectric constant23°CIEC602503.401MHz
Dissipation factor23°CIEC602500.0201MHz
Dissipation factor耐电弧性IEC6162170.0S
Dielectric constantASTM D150/IEC 602503.4
Volume resistivityASTM D257/IEC 600931.0x10^14Ω.cm
Dielectric strength短时·23℃·1/8时ASTM D-14917KV/mm
Volume resistivityASTM D-2571.0cm×10
Arc resistanceASTM D-49570
hardnessTest ConditionTest MethodTest ResultUnit
Rockwell hardnessISO2039-282M(Scale)
flammabilityTest ConditionTest MethodTest ResultUnit
Fire ratingUL-941.50mmV-0
Fire ratingUL-943.00mmV-0
Fire ratingUL-940.38mmV-0
Fire ratingUL-940.71mmV-0
Basic performanceTest ConditionTest MethodTest ResultUnit
Water absorption rate23℃·24hrASTM D-5700.08%
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.