Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density | | ASTM D792/ISO 1183 | 1.56 | |
Moisture Absorption 23℃/24H | | ASTM D570/ISO 62 | 0.07 | % |
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 23℃,24hr | ASTM D570 | 0.07 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
IZOD Notch Impact Strength | Notched,23℃ | ASTM D256 | 60 | J/m |
IZOD Notch Impact Strength | Unnotched,23℃ | ASTM D256 | 50 | KJ/m |
Tensile Elongation?(Break) | | ASTM D638/ISO 527 | 5 | % |
Tensile Strength | | ASTM D638/ISO 527 | 110 | kg/cm²(MPa)[Lb/in²] |
Tensile Strength | 23℃ | ASTM D638 | 110 | Mpa |
Tensile Elongation | 23℃ | ASTM D638 | 5 | % |
Rockwell Hardness | | ASTM D785 | 87 | M |
Rockwell Hardness | | ASTM D785 | M87 | |
Flexural Modulus | | ASTM D790/ISO 178 | 5600 | kg/cm²(MPa)[Lb/in²] |
Flexural Modulus | 23℃ | ASTM D790 | 5.6 | GPa |
Flexural Strength | 23℃ | ASTM D790 | 150 | Mpa |
Flexural Strength | | ASTM D790/ISO 178 | 150 | kg/cm²(MPa)[Lb/in²] |
Coefficient of Friction | -,对金属 | ASTM D1894 | 0.15 | |
Coefficient of Friction | -,对本身 | ASTM D1894 | 0.20 | |
Izod notch impact strength | | ASTM D256/ISO 179 | 60 | kg·cm/cm(J/M)ft·lb/in |
Izod notch impact strength | | ASTM D256/ISO 179 | 50 | kg·cm/cm(J/M)ft·lb/in |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Flame retardancy | | UL94 | V-0 | |
Burning Rate | | UL94 | V-0 | |
Deflection Temperature Under Load? | | ASTM D648/ISO 75 | 200 | ℃(℉) |
Deflection Temperature Under Load? | -,0.45MPa | ASTM D648 | 215 | °C |
Deflection Temperature Under Load? | -,1.82Mpa | ASTM D648 | 200 | °C |
Linear expansion coefficient | | ASTM D696/ISO 11359 | 5.3x10^-5 | mm/mm.℃ |
Coefficient of Linear Thermal Expansion | | ASTM D696 | 5.3 | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Arc Resistance | | ASTM D149 | 25 | MV/m |
Dissipation Factor?(Tangent) | -,50Hz | ASTM D150 | 0.002 | |
Dissipation Factor?(Tangent) | -,10 | ASTM D150 | 0.02 | |
Dielectric Constant | | ASTM D150/IEC 60250 | 3.8 | |
Dielectric Constant | -,50Hz | ASTM D150 | 3.6 | |
Dielectric Constant | -,10 | ASTM D150 | 3.8 | |
Volume Resistivity | | ASTM D257/IEC 60093 | 3.0x10^14 | Ω.cm |
Volume Resistivity | | ASTM D257 | 3.0 | |
Volume Resistivity | | ASTM D495 | 133 | S |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.