Need Help? Contact Us service@plas.com
Get App

PBT LONGLITE®  2100 TAIWAN CHANGCHUN

114
  • Unit Price:
    $3676 USD/MT
  • Packaging Specification:
    25 KG/PKG
  • Supply Quantity:
    20MT
  • Delivery Terms:
    FOB
  • Port of Loading:
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 2787 3515View
serv********View

For more detailed information including pricing, customization, and shipping, please contact supplier.

Material Description
Technical Data Sheet

Material Description

  • Material Properties:Flame retardant
  • Application Areas:Automotive sector
  • Color:--
  • Grade:Flame retardant grade

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
Shrinkage rateASTM D-9551.3-2.0%
Glass fiber contentAsh0%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
tensile elongation ASTM D-6384-6%
Flexural strengthASTM D-790900-1200kg/cm
Tensile strengthASTM D-638500-700kg/cm
Flexural elasticityASTM D-79025000-35000kg/cm
tensile strength ASTM D638/ISO 527700kg/cm²(MPa)[Lb/in²]
Rockwell hardnessASTM D78588
Rockwell hardnessASTM D-78588M-scale
IZOD notch impact strengthASTM D256/ISO 1792.5-3.5kg·cm/cm(J/M)ft·lb/in
IZOD impact strengthASTM D-2562.5-3.5kg.cm/cm
Thermal performanceTest ConditionTest MethodTest ResultUnit
Flame resistance0.75mmUL 94V-0
Hot deformation temperature18.6Kg/cmASTM D-64865°C
Hot deformation temperatureASTM D648/ISO 7565℃(℉)
Hot deformation temperatureASTM D648/ISO 75165℃(℉)
Hot deformation temperature4.6Kg/cmASTM D-648165°C
melting pointDSC225°C
Coefficient of linear expansionASTM D-6969
Electrical performanceTest ConditionTest MethodTest ResultUnit
permittivity 60HzASTM D-1503.2
Insulation breakdown strengthASTM D-14918KV/mm
Surface resistivityASTM D257/IEC 60093>10Ω
Surface resistivityASTM D-257>10Ω
Dielectric constantASTM D150/IEC 60250302
Dielectric constantASTM D150/IEC 602500.001
Arc resistanceASTM D495/IEC 60112120
Arc resistanceASTM D-495120sec
Volume resistivityASTM D-257>10Ω.cm
Induced positive connection60HzASTM D-1500.001
Basic performanceTest ConditionTest MethodTest ResultUnit
Water absorption rateASTM D-5700.05%
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.