Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | Flow ,80℃×2mmt | | 0.1 | % |
Modeling Shrinkage | Across Flow ,80℃×2mmt | | 0.6 | % |
Moisture Absorption | (23°C,24hr) | ISO62 | 0.04 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Fracture strain | | ISO 527-1,2 | 1.3 | % |
Tensile Elongation?(Break) | 23°C | ISO527-2 | 1.3 | % |
Tensile Strength | 23°C | ISO527-2 | 215 | Mpa |
Tensile Strength | | ISO 527-1,2 | 215 | Mpa |
Flexural Modulus | | ISO 178 | 21200 | Mpa |
Flexural Modulus | 23°C | ISO178 | 21200 | Mpa |
Flexural Strength | | ISO 178 | 300 | Mpa |
Flexural Strength | 23°C | ISO178 | 300 | Mpa |
Charpy Notched Impact Strength | | ISO 179/1eA | 5.5 | KJ/m |
Charpy Notched Impact Strength | 23°C | ISO179/1eA | 5.5 | kJ/m² |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Coefficient of Linear Thermal Expansion | Flow | ISO 11359-2 | 1 | |
Coefficient of Linear Thermal Expansion | Across Flow | - | 4 | |
Deflection Temperature Under Load? | 1.80MPaAnnealed | ISO75-2/Af | 265 | °C |
Deflection Temperature Under Load? | 1.8MPa | ISO 75-1 | 265 | °C |
Coefficient of Linear Thermal Expansion | MD | ISO11359-2 | 1E-05 | cm/cm/°C |
Coefficient of Linear Thermal Expansion | TD | ISO11359-2 | 4E-05 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Volume Resistivity | | IEC60093 | 2E+03 | Ω.cm |
Surface Resistivity | | IEC 60093 | 200 | Ω |
Volume Resistivity | | IEC 60093 | 2000 | Ω·cm |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | | ISO2039-2 | 110 | M(Scale) |
Other | Test Condition | Test Method | Test Result | Unit |
---|
Melt Viscosity | 310℃、1000/sec | ISO 11443 | 380 | Pa·s |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 23℃、水中24hr | ISO 62 | 0.02 | % |
Density | | ISO 1183 | 1.44 | g/cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.