Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density | | ASTM D792/ISO 1183 | 1.95 | |
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 23°C,24hr | ISO62 | 0.030 | % |
Melt Viscosity | 310°C,1000sec^-1 | ISO11443 | 280000 | mPa·s |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Notched Impact Strength | | J/m | ASTM D256 | 75 |
Charpy Notched Impact Strength | | kJ/m² | ISO 179/1eA | 6.0 |
Flexural Stress | | ISO178 | 200 | Mpa |
Tensile Stress | | ISO527-2 | 140 | Mpa |
Tensile Strain | Break | ISO527-2 | 1.0 | % |
Tensile Stress(Yield) | | MPa | ISO 527-2 | 140 |
Tensile Stress(Yield) | | MPa | ASTM D638 | 145 |
Tensile Strength | | ASTM D638/ISO 527 | 140 | kg/cm²(MPa)[Lb/in²] |
Tensile Elongation | Break | % | ASTM D638 | 1.2 |
Tensile Elongation | Break | % | ISO 527-2 | 1.0 |
Flexural Modulus | | MPa | ASTM D790 | |
Flexural Modulus | | MPa | ISO 178 | |
Flexural Modulus | | ASTM D790/ISO 178 | 19000 | kg/cm²(MPa)[Lb/in²] |
Flexural Modulus | | ISO178 | 19000 | Mpa |
Flexural Strength | | ASTM D790/ISO 178 | 200 | kg/cm²(MPa)[Lb/in²] |
Flexural Strength | | MPa | ASTM D790 | |
Flexural Strength | | MPa | ISO 178 | |
Tensile Elongation?(Break) | | ASTM D638/ISO 527 | 1 | % |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | | | UL 94 | V0 |
Burning Rate | | UL94 | V-0 | |
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ℃ | ASTM D648 | 275 |
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ℃ | ISO 75-2A | 270 |
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ISO75-2/A | 270 | °C |
Linear thermal expansion coefficient | MD | 内部方法 | 1E-05 | cm/cm/°C |
Linear thermal expansion coefficient | TD | 内部方法 | 3E-05 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric Strength | 3.00mm | IEC60243-1 | 15 | KV/mm |
Relative Permittivity | 1kHz | IEC60250 | 4.80 | |
Relative Permittivity | 1MHz | IEC60250 | 4.80 | |
Comparative Tracking Index | | IEC60112 | 175 | V |
Volume Resistivity | | IEC60093 | 2E+15 | ohms·cm |
Dissipation Factor? | 1kHz | IEC60250 | 2E-03 | |
Dissipation Factor? | 1MHz | IEC60250 | 2E-03 | |
Dissipation Factor? | 耐电弧性 | IEC60250 | 170 | sec |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | M-Scale | ISO2039-2 | 105 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | | UL94 | V-0 | |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Melt Viscosity | | Pa.s | ISO 11443 | 280 |
Melt Viscosity | | Pa.s | ASTM D3835 | 270 |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|
Color Number | | | HD9050 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.