Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 23°C,24hr | ISO62 | 0.040 | % |
Melt Viscosity | 310°C,1000sec^-1 | ISO11443 | 260000 | mPa·s |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Fracture strain | | ISO 527-1,2 | 1.9 | % |
Tensile Stress | | ISO527-2 | 185 | Mpa |
Tensile Strain | Break | ISO527-2 | 1.7 | % |
Tensile Strength | | ISO 527-1,2 | 210 | Mpa |
Flexural Modulus | | ISO178 | 13200 | Mpa |
Flexural Modulus | | ISO 178 | 13800 | Mpa |
Flexural Strength | | ISO 178 | 280 | Mpa |
Charpy Notched Impact Strength | | ISO 179/leA | 10 | KJ/m |
Flexural Stress | | ISO178 | 260 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Linear thermal expansion coefficient | MD | 内部方法 | 1E-05 | cm/cm/°C |
Linear thermal expansion coefficient | TD | 内部方法 | 4E-05 | cm/cm/°C |
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ISO75-2/A | 265 | °C |
Flame retardancy | | UL 94 | V-0 | |
Deflection Temperature Under Load? | 1.8MPa | ISO 75-1,2 | 270 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Volume Resistivity | | IEC60093 | 5E+15 | ohms·cm |
Dissipation Factor? | 1kHz | IEC60250 | 1E-03 | |
Dissipation Factor? | 1MHz | IEC60250 | 2E-03 | |
Dielectric Strength | 3.00mm | IEC60243-1 | 16 | KV/mm |
Relative Permittivity | 1kHz | IEC60250 | 4.50 | |
Relative Permittivity | 1MHz | IEC60250 | 4.50 | |
Comparative Tracking Index | | IEC60112 | 125 | V |
Other | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | | ISO 62 | 0.01 | % |
Melt Viscosity | 310℃、1000sec | ISO 11443 | 260 | Pa.s |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | | UL94 | V-0 | |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Density | | ISO 1183 | 1.66 | g/cm |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|
Color Number | | | HD9100,HD9001 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.