Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | MD | ASTMD955 | 0.10to0.20 | % |
Shrinkage rate | TD | ASTMD955 | 0.30to0.50 | % |
Shrinkage rate | TD | ISO294-4 | 0.30to0.70 | % |
Shrinkage rate | MD | ISO294-4 | 0.20to0.60 | % |
Water absorption rate | Saturation,23°C | ISO62 | 0.020 | % |
Mold shrinkage rate | | ISO 2577 | 0.2-0.6 | % |
SpecificHeatCapacity of Melt | | 内部方法 | 1600 | J/kg/°C |
Specific volume | | ASTMD792 | 0.502 | cm³/g |
Density/specific gravity | | ISO1183 | 1.95 | g/cm³ |
Density/specific gravity | | ASTMD792 | 2.00 | g/cm³ |
Density/specific gravity | | ISO 1183 | 1.95 | g/cm³ |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile stress | Break | ISO527-2/1A/5 | 130 | Mpa |
Tensile strain | Break | ISO527-2/1A/5 | 1.2 | % |
Bending stress 2 | | ISO178 | 210 | Mpa |
Tensile strength | Break,23°C | ASTMD638 | 114 | Mpa |
IZOD notch impact strength | 23℃ | ISO 180/1A | 6 | kJ/m² |
Tensile modulus | | ISO 527-1 | 19000 | Mpa |
Tensile modulus | | ISO527-2/1A/1 | 19000 | Mpa |
tensile strength | | ISO 527-1 | 130 | Mpa |
elongation | Break | ISO 527-1 | 1.2 | % |
elongation | Break,23°C | ASTMD638 | 1.3 | % |
Rockwell hardness | | ISO 2039-2 | 100 | M-scale |
Bending modulus | | ISO 178 | 18800 | Mpa |
Bending modulus | 23°C | ISO178 | 18800 | Mpa |
bending strength | | ISO 178 | 210 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Hot deformation temperature | 1.80Mpa | ISO 75-1 | 270 | °C |
Hot deformation temperature | 0.45MPa,Annealed | ASTMD648 | 280 | °C |
Hot deformation temperature | 1.8MPa,Unannealed | ASTMD648 | 266 | °C |
Hot deformation temperature | 1.8MPa,Unannealed | ISO75-2/A | 270 | °C |
Hot deformation temperature | 8.0MPa,Unannealed | ISO75-2/C | 215 | °C |
Linear coefficient of thermal expansion | MD | ISO11359-2 | 1.9E-05 | cm/cm/°C |
Linear coefficient of thermal expansion | TD | ISO11359-2 | 2.4E-05 | cm/cm/°C |
Flame retardant grade | 0.750mm | UL94 | V-0 | |
Melting temperature 5 | | ISO11357-3 | 280 | °C |
Glass transition temperature 3 | | ISO11357-2 | 90.0 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Relative permittivity | 1MHz | IEC60250 | 5.60 | |
Leakage Trace Index | | IEC60112 | 175 | V |
Dielectric strength | | IEC60243-1 | 25 | KV/mm |
Dissipation factor | 1kHz | ASTMD150 | 1E-03 | |
Dissipation factor | 1MHz | ASTMD150 | 9E-04 | |
Dissipation factor | 1MHz | IEC60250 | 2E-03 | |
Surface resistivity | | IEC60093 | >1.0E+15 | ohms |
Dielectric constant | 1kHz | ASTMD150 | 4.50 | |
Dielectric constant | 1MHz | ASTMD150 | 4.50 | |
Arc resistance | | ASTMD495 | 182 | sec |
Volume resistivity | | ASTMD257 | 1E+16 | ohms·cm |
Volume resistivity | | IEC60093 | >1.0E+15 | ohms·cm |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Impact strength of simply supported beam without notch | -30°C | ISO179/1eU | 20 | kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO179/1eU | 20 | kJ/m² |
Unscented Izod impact strength | 23°C | ISO180/1U | 20 | kJ/m² |
Charpy Notched Impact Strength | -30°C | ISO179/1eA | 7.0 | kJ/m² |
Charpy Notched Impact Strength | 23°C | ISO179/1eA | 7.0 | kJ/m² |
Impact strength of cantilever beam gap | -30°C | ISO180/1A | 6.0 | kJ/m² |
Impact strength of cantilever beam gap | 23°C | ISO180/1A | 6.0 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell hardness | M-Scale | ASTMD785 | 100 | |
Rockwell hardness | M-Scale | ISO2039-2 | 100 | |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 0.75mm | UL94 | V-0 | |
UL flame retardant rating | 1.5mm | UL94 | V-0 | |
Basic performance | Test Condition | Test Method | Test Result | Unit |
---|
Water absorption rate | 23℃ | ISO 62 | 0.02 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.