Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density | | ASTM D792/ISO 1183 | 1660 | |
Moisture Absorption 23℃/24H | | ASTM D570/ISO 62 | 0.02 | % |
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | Flow | 东丽法 | 0.20 | % |
Modeling Shrinkage | 垂重方向 | 东丽法 | 0.70 | % |
Spiral Flow | 320℃,98MPa,1mm厚 | 东丽法 | 124 | |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Taber Abrasion Resistance | | ASTM D-1044 | 50 | mg/1000回 |
PV | | 东丽法 | 东丽法 | KJ/m |
Flexural Strength | | ASTM D-790 | 13.7 | GPa |
hardness | | ASTM D-785 | 120 | 洛氏 |
Tensile Strength(Break) | | ASTM D-732 | 75 | |
Tensile strength | | ASTM D-638 | 155 | Mpa |
Coefficient of Friction | 对钢 | ASTM D-1894 | 0.25 | |
Impact Strength | Notched23℃ | ASTM D-256 | 100 | J/m |
Impact Strength | Unnotched23℃ | ASTM D-256 | 30 | KJ/m |
Tensile Strength | | ASTM D638/ISO 527 | 165 | kg/cm²(MPa)[Lb/in²] |
Tensile Strength | | ASTM D-638 | 1.6 | % |
Tensile Elongation | | ASTM D638/ISO 527 | 1.4 | % |
Rockwell Hardness | | ASTM D785 | R-123 | |
Flexural Strength | | ASTM D790/ISO 178 | 250 | kg/cm²(MPa)[Lb/in²] |
Flexural Strength | | ASTM D-790 | 205 | Mpa |
Charpy impact strength | | ASTM D256/ISO 179 | 30 | kg·cm/cm(J/M)ft·lb/in |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Flammability | | UL-94 | V-0 | |
Burning Rate | | UL94 | V-0 (0.28mmt) | |
Deflection Temperature Under Load? | | ASTM D648/ISO 75 | >260 | ℃(℉) |
Deflection Temperature Under Load? | 1.82MPa | ASTM D-648 | >260 | °C |
Melting Temperature | | DSC | 278 | °C |
Coefficient of Linear Thermal Expansion | Flow | ASTM D-696 | 2.2 | |
Coefficient of Linear Thermal Expansion | 垂重方向 | ASTM D-696 | 3.3 | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Arc Resistance | | ASTM D-495 | 127 | 秒 |
Dissipation Factor | 10 | ASTM D-150 | 3.8 | |
Dielectric Constant | 10 | ASTM D-150 | 0.002 | |
Volume Resistivity | | ASTM D-257 | 10 | Ω.m |
Insulation Resistance | | ASTM D-149 | 21 | MV/m |
Dielectric Constant | | ASTM D150/IEC 60250 | 3.6 | |
Volume Resistivity | | ASTM D257/IEC 60093 | 10^14 | Ω.cm |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | | ASTM D-570 | 0.02 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.