Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density | | ASTM D792/ISO 1183 | 1.81 | |
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | TD:1.00mm | 内部方法 | 0.40 | % |
Modeling Shrinkage | MD:1.00mm | 内部方法 | 0.11 | % |
Moisture Absorption | 23°C,24hr | ISO62 | 0.020 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Flexural Stress | | ISO178 | 260 | Mpa |
Tensile Strength | | ASTM D638/ISO 527 | 180 | kg/cm²(MPa)[Lb/in²] |
Tensile Elongation | Break | ASTMD638 | 1.5 | % |
Flexural Modulus | | ISO178 | 20500 | Mpa |
Flexural Modulus | | ASTM D790/ISO 178 | 20500 | kg/cm²(MPa)[Lb/in²] |
Flexural Strength | | ASTM D790/ISO 178 | 260 | kg/cm²(MPa)[Lb/in²] |
Flexural Strain | | ISO178 | 1.8 | % |
Tensile Strength | | ASTMD638 | 180 | Mpa |
Charpy impact strength | | ASTM D256/ISO 179 | 12 | kg·cm/cm(J/M)ft·lb/in |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ISO75-2/A | 240 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric Constant | | ASTM D150/IEC 60250 | 4.1 | |
Volume Resistivity | | IEC60093 | 1E+16 | ohms·cm |
Dielectric Strength | 1.00mm | IEC60243-1 | 44 | KV/mm |
Dielectric Strength | 3.00mm | IEC60243-1 | 28 | KV/mm |
Relative Permittivity | 1kHz | IEC60250 | 4.50 | |
Relative Permittivity | 1MHz | IEC60250 | 4.10 | |
Comparative Tracking Index | | IEC60112 | 200 | V |
Dissipation Factor? | 1kHz | IEC60250 | 0.020 | |
Dissipation Factor? | 1MHz | IEC60250 | 0.020 | |
Dissipation Factor? | 耐电弧性 | IEC60250 | 180 | sec |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | M-Sale | ISO2039-2 | 90 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | | UL94 | V-0 | |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|
Color Number | | | VF2001/BK210P | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.