Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | Across Flow : 24hr | ISO 294-4 | 0.50 | % |
Modeling Shrinkage | 流量 : 24hr | ISO 294-4 | 0.40 到 0.70 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Stress | Yield | ISO 527-2 | 57.0 | Mpa |
Tensile Stress | Break | ISO 527-2 | 55.0 | Mpa |
Tensile Strain | Yield | ISO 527-2 | 3.8 | % |
Tensile Strain | Break | ISO 527-2 | 4.0 到 8.0 | % |
Flexural Stress | | ISO 178 | 80.0 | Mpa |
Tensile Modulus | | ISO 527-2/1 | 2800 | Mpa |
Flexural Modulus | | ISO 178 | 2600 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Heat Deflection Temperature | 0.45 MPa, Unannealed, 4.00 mm, 64.0 mm Span | ISO 75-2/Bf | 136 | °C |
Heat Deflection Temperature | 1.8 MPa, Unannealed, 4.00 mm, 64.0 mm Span | ISO 75-2/Af | 125 | °C |
Linear thermal expansion coefficient | Flow : -40 to 40°C | ISO 11359-2 | 6.7E-5 | cm/cm/°C |
Linear thermal expansion coefficient | Across Flow : -40°C | ISO 11359-2 | 5.6E-5 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
EMI Attenuation | 3.00 mm | 内部方法 | 40 到 55 | dB |
Surface Resistivity | | ASTM D257 | 1.0E+2 到 1.0E+3 | ohms |
Volume Resistivity | | ASTM D257 | 1.0E+4 | ohms·cm |
Injection | Test Condition | Test Method | Test Result | Unit |
---|
Drying Temperature | | | 120 | °C |
Suggested Max Moisture | | | 0.020 | % |
Processing (Melt) Temp | | | 305 到 325 | °C |
Mold Temperature | | | 95 到 120 | °C |
Drying Time | | | 4.0 | hr |
Rear Temperature | | | 295 到 305 | °C |
Middle Temperature | | | 310 到 320 | °C |
Front Temperature | | | 320 到 330 | °C |
Back Pressure | | | 0.200 到 0.300 | Mpa |
Screw Speed | | | 30 到 60 | rpm |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Unnotched Izod Impact Strength | 23°C | ASTM D4812 | 1800 | J/m |
Unnotched Izod Impact Strength | 23°C 2 | ISO 180/1U | 85 | kJ/m² |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | 2.1 mm, Testing by SABIC | UL 94 | V-0 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.