Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 24 hr | ASTM D570 | 0.15 | % |
Moisture Absorption | Equilibrium, 23°C | ASTM D570 | 0.35 | % |
Moisture Absorption | Equilibrium, 100°C | ASTM D570 | 0.58 | % |
Melt Mass-Flow Rate | 300°C/1.2 kg | ASTM D1238 | 18 | g/10 min |
Modeling Shrinkage - Flow | 3.20 mm | 内部方法 | 0.50 到 0.70 | % |
Specific Volume | | ASTM D792 | 0.830 | cm³/g |
Outdoor Suitability | | UL 746C | f2 | |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Strength | Yield | ASTM D638 | 62.0 | Mpa |
Tensile Strength | Break | ASTM D638 | 65.0 | Mpa |
Tensile Elongation | Yield | ASTM D638 | 7.0 | % |
Tensile Elongation | Break | ASTM D638 | 110 | % |
Flexural Modulus | 50.0 mm Span | ASTM D790 | 2340 | Mpa |
Flexural Strength | Yield, 50.0 mm Span | ASTM D790 | 93.0 | Mpa |
Taber Abrasion Resistance | 1000 Cycles, 1000 g, CS-17 Wheel | ASTM D1044 | 10.0 | mg |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Specific Heat | | ASTM C351 | 1260 | J/kg/°C |
Thermal Conductivity | | ASTM C177 | 0.25 | W/m/K |
RTI | | UL 746 | 80.0 | °C |
RTI Imp | | UL 746 | 80.0 | °C |
RTI Elec | | UL 746 | 80.0 | °C |
Coefficient of Linear Thermal Expansion (Flow) | -40 to 95°C | ASTM E831 | 6.8E-5 | cm/cm/°C |
Deflection Temperature Under Load? | 0.45 MPa, Unannealed, 6.40 mm | ASTM D648 | 137 | °C |
Deflection Temperature Under Load? | 1.8 MPa, Unannealed, 6.40 mm | ASTM D648 | 132 | °C |
Ball PressureTest | 123 to 127°C | IEC 60695-10-2 | 通过 | |
Vicat Softening Temperature | | ASTM D15257 | 154 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
High Amp Arc Ignition | | UL 746 | PLC 1 | |
Comparative Tracking Index | | UL 746 | PLC 3 | |
Hot-wire Ignition | | UL 746 | PLC 3 | |
Dielectric Constant | 60 Hz | ASTM D150 | 3.17 | |
Dielectric Constant | 50 kHz | ASTM D150 | 3.17 | |
Dielectric Constant | 1 MHz | ASTM D150 | 2.96 | |
Volume Resistivity | | ASTM D257 | > 1.0E+17 | ohms·cm |
Dissipation Factor? | 50 Hz | ASTM D150 | 9.0E-4 | |
Dissipation Factor? | 60 Hz | ASTM D150 | 9.0E-4 | |
Dissipation Factor? | 1 MHz | ASTM D150 | 0.010 | |
Dielectric Strength | 3.20 mm, in Air | ASTM D149 | 15 | KV/mm |
Injection | Test Condition | Test Method | Test Result | Unit |
---|
Drying Time | | | 3.0 到 4.0 | hr |
Suggested Shot Size | | | 40 到 60 | % |
Rear Temperature | | | 260 到 280 | °C |
Middle Temperature | | | 270 到 295 | °C |
Front Temperature | | | 280 到 305 | °C |
Nozzle Temperature | | | 275 到 300 | °C |
Back Pressure | | | 0.300 到 0.700 | Mpa |
Screw Speed | | | 40 到 70 | rpm |
Vent Depth | | | 0.025 到 0.076 | mm |
Drying Temperature | | | 120 | °C |
Suggested Max Moisture | | | 0.020 | % |
Processing (Melt) Temp | | | 280 到 305 | °C |
Mold Temperature | | | 70 到 95 | °C |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Gardner Impact | 23°C | ASTM D3029 | 169 | J |
Unnotched Izod Impact Strength | 23°C | ASTM D4812 | 3200 | J/m |
Unnotched Izod Impact Strength | -30°C 5 | ISO 180/1U | 无断裂 | |
Unnotched Izod Impact Strength | 23°C 5 | ISO 180/1U | 无断裂 | |
Tensile Impact Strength | | ASTM D1822 | 546 | kJ/m² |
Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 12 | kJ/m² |
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 65 | kJ/m² |
Charpy Unnotched Impact Strength | -30°C | ISO 179/1eU | 无断裂 | |
Charpy Unnotched Impact Strength | 23°C | ISO 179/1eU | 无断裂 | |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | M-Scale | ASTM D785 | 70 | |
Rockwell Hardness | R-Scale | ASTM D785 | 118 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Glow Wire Flammability Index | 0.75 mm | IEC 60695-2-12 | 750 | °C |
Glow Wire Flammability Index | 1.5 mm | IEC 60695-2-12 | 850 | °C |
Glow Wire Ignition Temperature | 0.75 mm 9 | IEC 60695-2-13 | 875 | °C |
Glow Wire Ignition Temperature | 1.5 mm | IEC 60695-2-13 | 850 | °C |
Flame Rating | 0.8 to 1.7 mm | UL 94 | V-2 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.