Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | TD | Internal Method | 0.6 | % |
Modeling Shrinkage | MD: 2.00 mm | Internal Method | 0.4 | % |
Modeling Shrinkage | TD:2.00mm | 内部方法 | 0.60 | % |
Modeling Shrinkage | MD:2.00mm | 内部方法 | 0.40 | % |
Moisture Absorption | Equilibrium, 23℃, 50% RH | ISO 62 | 0.15 | % |
Spiral Flow | | 内部方法 | 21.0 | CM |
Moisture Absorption | Equilibrium,23°C,50%RH | ISO62 | 0.15 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Nominal Tensile Strain at Break | | ISO527-2 | 5.0 | % |
Charpy Notched Impact Strength | | ISO 179 | 8 | kJ/m² |
Flexural Stress | | ISO178 | 120 | Mpa |
Tensile Stress | Yield | ISO527-2 | 80.0 | Mpa |
Tensile Stress | Break | ISO 527-2 | 80 | Mpa |
Tensile Strain | Break | ISO 527-2 | 5 | % |
Rockwell Hardness | M -Sale | ISO 2039-2 | 65 | |
Flexural Modulus | | ISO178 | 3500 | Mpa |
Flexural Modulus | | ISO 178 | 3500 | Mpa |
Flexural Strength | | ISO 178 | 120 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | 1.8 MPa, Unannealed | ISO 75-2/A | 142 | °C |
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ISO75-2/A | 142 | °C |
Linear thermal expansion coefficient | MD | ISO11359-2 | 4.5E-05 | cm/cm/°C |
Coefficient of Linear Thermal Expansion (Flow) | | ISO 11359-2 | 0.000045 | cm/cm/℃ |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric Strength | | IEC60243-1 | >22 | KV/mm |
Dielectric Constant | 1MHz | IEC60250 | 2.95 | |
Volume Resistivity | | ASTMD257 | >1.0E+16 | ohms·cm |
Dissipation Factor? | 1MHz | IEC60250 | 9E-03 | |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | M-Scale | ISO2039-2 | 65 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | 0.70mm | UL94 | HB | |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|
ISO Shortname | | | >PC-GF10< | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.