PC LEXAN™ 940 NC SABIC INNOVATIVE SINGAPHORE
172
- Unit Price:
- $2821 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 10MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515
serv********
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:Medium viscosity Flame retardant Medium viscosity
- Application Areas:Electrical field Electronic field Household appliances
- Color:--
- Grade:Injection grade
Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Modeling Shrinkage | 3.2mm | ASTM D-955 | 5-7 | |
Density / Specific Gravity | --- | ASTM D-792 | 1.21 | --- |
Flame retardancy | --- | UL 94 | 1.6 | mm |
--- | UL 94 | V-2 | --- | |
--- | UL 94 | 3.0 | mm | |
--- | UL 94 | V-0 | --- |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Notched Impact Strength | 23℃ | ASTM D-256 | 640 | J/m |
Tensile Elongation?(Break) | --- | ASTM D-638 | 90 | % |
Tensile Strength | Yield点,--- | ASTM D-638 | 62 | Mpa |
Break点,--- | ASTM D-638 | 56 | Mpa | |
Rockwell Hardness | --- | ASTM D-785 | 118 | --- |
Flexural Modulus | --- | ASTM D-790 | 3250 | Mpa |
Flexural Strength | --- | ASTM D-790 | 91 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Deflection Temperature Under Load? | 0.45MPa | ASTM D-648 | 137 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Dielectric Constant | 60Hz | ASTM D-150 | 3.01 | --- |
1MHz | ASTM D-150 | 2.96 | --- | |
Volume Resistivity | --- | ASTM D-257 | 1.0×10 | Ω.cm |
Loss factor | 1MHz | ASTM D-150 | 0.01 | --- |
60Hz | ASTM D-150 | 0.0009 | --- |
Physical | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Moisture Absorption | --- | ASTM D-570 | 0.15 | % |
Melt index | --- | ASTM D-1238 | 7 | g/10min |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.