PC CALIBRE™ 5101-15 STYRON US
82
- Unit Price:
- $5615 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 10MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515
serv********
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:Low shrinkage High modulus High thermal deformation Biocompatibility
- Application Areas:IT equipment Medical applications
- Color:--
- Grade:Medical grade
Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Melt index | ASTM D1238 | 15 | g/10min | |
Modeling Shrinkage | ASTM D955 | 0.2-0.5 | mm/mm | |
Density / Specific Gravity | ASTM D792 | 1270 | kg/m |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile Elongation (Break) | ASTM D638 | -- | % | |
Tensile Strength(Break) | ASTM D638 | 61 | Mpa | |
IZOD Notch Impact Strength | 23℃ | ASTM D1256 | 80 | J/m |
Tensile Strength(Yield) | ASTM D638 | 62 | Mpa | |
Tensile Elongation?(Break) | ASTM D638 | 6 | % | |
Tensile Modulus | ASTM D638 | 3380 | Mpa | |
Flexural Modulus | 23℃ | ASTM D790 | 3170 | Mpa |
Flexural Strength | 23℃ | ASTM D790 | 94 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Deflection Temperature Under Load? | -,Annealed,0.45MPa | ASTM D648 | 144 | °C |
-,Unannealed,1.82MPa | ASTM D648 | 134 | °C | |
Vicat Softening Temperature | ASTM D1525 | 160 | °C | |
Flame retardancy | -,1.6mm | UL94 | V-2 | |
-,3.2mm | UL94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.