Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | | ISO 2577 | 2.1 | % |
Moisture Absorption | | ISO 62 | 0.80 | % |
Rockwell Hardness | | ASTM D785 | 85 | R |
Density / Specific Gravity | | ISO 1183 | 0.0506 | lb/in |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Elongation (Break) | | ASTM D638 | 10 | % |
Notched Izod Impact Strength | -40℉ | ASTM D256 | 1.03 | ft·lb/in |
Notched Izod Impact Strength | 73℉ | ASTM D256 | 1.20 | ft·lb/in |
Tensile Stress (Yield) | | ISO 527-1,-2 | 10 | % |
Tensile Stress (Yield) | | ISO 527-1,-2 | 8850 | psi |
Tensile Strength(Yield) | | ASTM D638 | 8850 | psi |
Tensile Creep Modulus | 1h | ISO 899-1 | 276000 | psi |
Tensile Creep Modulus | 1000h | ISO 899-1 | 189000 | psi |
Charpy Notched Impact Strength | | ISO 179/1eA | 2.62 | ft·lb/in |
Tensile Modulus | | ASTM D638 | 377000 | psi |
Tensile Modulus | | ISO 527-1,-2 | 377000 | psi |
Flexural Modulus | 73℉ | ASTM D790 | 339000 | psi |
Charpy impact strength | 23℃ | ISO 179/1eU | 95.2 | ft·lb/in |
Charpy impact strength | -30℃ | ISO 179/1eU | 85.7 | ft·lb/in |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | 0.45MPa | ISO 75-1,-2 | 203 | ℉ |
Deflection Temperature Under Load? | 1.80MPa | ISO 75-1,-2 | 221 | ℉ |
Melting Temperature | | | 331 | ℉ |
Vicat Softening Temperature | | ISO 306 | 302 | ℉ |
Flame retardancy | | ISO 1210 | HB | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Volume Resistivity | | IEC 60093 | 3.9E+11 | ohm·in |
Dielectric Constant | 100HZ | IEC 60250 | 3.80 | |
Dielectric Constant | 1MHz | IEC 60250 | 3.80 | |
Surface resistance | | IEC 60093 | 1E+12 | ohms |
Other | Test Condition | Test Method | Test Result | Unit |
---|
Oxygen Index | | ISO 4589-1,-2 | 15 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.