Physical PropertiesTest ConditionTest MethodTest ResultUnit
Modeling ShrinkageMD内部方法1.6到2.0%
Moisture Absorption23°C,24hr,50%RHASTMD5700.20%
Melt Mass-Flow Rate190°C/2.16kgISO11339.0g/10min
Mechanical PropertiesTest ConditionTest MethodTest ResultUnit
Taber Abrasion ResistanceASTMD104414.0mg
Tensile StressYieldISO527-261.0Mpa
Tensile Stress--ASTMD63862.0Mpa
Tensile ModulusISO527-22500Mpa
Tensile ElongationBreakASTMD63842%
Tensile ElongationBreakISO527-235%
Flexural Modulus--ASTMD7902450Mpa
Flexural Modulus--ISO1782350Mpa
Flexural StrengthASTMD79088.0Mpa
Thermal PropertiesTest ConditionTest MethodTest ResultUnit
Deflection Temperature Under Load?0.45MPa,UnannealedASTMD648158°C
Deflection Temperature Under Load?0.45MPa,UnannealedISO75-2/B152°C
Deflection Temperature Under Load?1.8MPa,UnannealedASTMD648110°C
Deflection Temperature Under Load?1.8MPa,UnannealedISO75-2/A91.0°C
Linear thermal expansion coefficientMDASTMD696,ISO11359-21E-04cm/cm/°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Dielectric StrengthASTMD14919KV/mm
Surface ResistivityASTMD2571.0E+16到1.0E+17ohms
Arc ResistanceASTMD495250sec
Volume Resistivity23°CASTMD2571.0E+15到1.0E+16ohms·cm
hardnessTest ConditionTest MethodTest ResultUnit
Rockwell HardnessR-ScaleASTMD785115
Rockwell HardnessM-ScaleASTMD78580
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.