Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Transmittance | 3.2mm | ASTM D-1003 | 93 | % |
Index of Refraction | | ASTM D-542 | 1.49 | |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
flexural modulus | | ASTM D-790 | 33,000 | kg/cm |
Melt index | 230°C,3.8kg | ASTM D-1238 | 5.8 | g/10min |
Rockwell Hardness | M-Scale | ASTM D-785 | 93 | |
Flexural Strength | | ASTM D-790 | 1,220 | kg/cm |
Impact Strength | Izod Notched | ASTM D-256 | 1.6 | kg·cm/cm |
Tensile Elongation | | ASTM D-638 | 3.5 | % |
Tensile Stress | | ASTM D-638 | 710 | kg/cm |
Modeling Shrinkage | | ASTM D995-51 | 0.2-0.6 | % |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Coefficient of Linear Thermal Expansion | | ASTM D-696 | 6×10 | cm/cm/°C |
Thermal Conductivity | | ASTM D-177 | 5×10 | cal/seccm·°C/cm |
Deflection Temperature Under Load? | 18.56kg | ASTM D-648 | 96 | °C |
Vicat Softening Temperature | 1kg | ASTM D-1525 | 100 | °C |
Specific Heat | | | 0.35 | cal/g/°C |
Burning rate | 1/8",1/16" | UL94 | HB | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric Constant | 60Hz | ASTM D-150 | 4 | |
功率系数 | 60Hz | ASTM D-150 | 0.05 | |
Volume Resistivity | | ASTM D-257 | >15 | Ω.m |
Dielectric Strength | 4KV/S | ASTM D-149 | 20 | KV/mm |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 24h | ASTM D-570 | 0.3 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.