PA66 LNP™ KONDUIT™ PX11313 WH9G331 SABIC INNOVATIVE US
81
- Unit Price:
- $5209 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 22MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:Non chloro non bromine fl heat conduction
- Application Areas:Electronic display Lighting applications Electronic and Electrical
- Color:--
- Grade:--
Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Modeling Shrinkage | Flow : 24hr | ASTM D955 | 0.42 | % |
Across Flow : 24hr | ASTM D955 | 0.58 | % | |
Moisture Absorption | 24 hr, 23°C | ISO 62 | 0.040 | % |
24 hr, 23°C 2 | ISO 62 | 0.23 | % | |
Equilibrium, 23°C, 50% RH | ISO 62 | 0.040 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile Strength | Break 4 | ASTM D638 | 98.0 | Mpa |
Break | ISO 527-2/5 | 108 | Mpa | |
Tensile Modulus | -- 3 | ASTM D638 | 13300 | Mpa |
-- | ISO 527-2/1 | 13300 | Mpa | |
Tensile Elongation | Break 4 | ASTM D638 | 1.3 | % |
Break | ISO 527-2/5 | 1.3 | % | |
Flexural Modulus | 50.0 mm Span 5 | ASTM D790 | 12500 | Mpa |
-- 6 | ISO 178 | 13000 | Mpa | |
Flexural Stress | -- 6, 7 | ISO 178 | 186 | Mpa |
Yield, 50.0 mm Span 5 | ASTM D790 | 167 | Mpa | |
Break, 50.0 mm Span 5 | ASTM D790 | 176 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Linear thermal expansion coefficient | Flow : 40 to 120°C | ASTM E831 | 4.1E-5 | cm/cm/°C |
Across Flow : 40 to 120°C | ASTM E831 | 8.5E-5 | cm/cm/°C | |
Thermal Conductivity | -- 9 | ASTM E1461 | 1.4 | W/m/K |
-- 10 | ASTM E1461 | 1.8 | W/m/K | |
-- 11 | ISO 22007-2 | 0.90 | W/m/K | |
-- 12 | ISO 22007-2 | 1.9 | W/m/K | |
RTI | UL 746 | 120 | °C | |
RTI Imp | UL 746 | 105 | °C | |
RTI Elec | UL 746 | 130 | °C | |
Deflection Temperature Under Load? | 0.45 MPa, Unannealed, 3.20 mm | ASTM D648 | 227 | °C |
0.45 MPa, Unannealed, 4.00 mm, 64.0 mm Span 8 | ISO 75-2/Bf | 228 | °C | |
1.8 MPa, Unannealed, 6.40 mm | ASTM D648 | 215 | °C | |
1.8 MPa, Unannealed, 4.00 mm, 64.0 mm Span 8 | ISO 75-2/Af | 208 | °C | |
Ball PressureTest | 123 to 127°C | IEC 60695-10-2 | 通过 |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Dissipation Factor? | 1.10 GHz | ASTM ES7-83 | 9.9E-3 | |
Surface Resistivity | ASTM D257 | > 1.0E+15 | ohms | |
Dielectric Constant | 1.10 GHz | ASTM ES7-83 | 4.84 | |
Dielectric Strength | 1.00 mm, in Oil | ASTM D149 | > 10 | KV/mm |
Comparative Tracking Index | IEC 60112 | 600 | V | |
Hot-wire Ignition | UL 746 | PLC 3 | ||
High Amp Arc Ignition | UL 746 | PLC 0 |
Injection | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Drying Time | 4.0 | hr | ||
Rear Temperature | 260 到 275 | °C | ||
Middle Temperature | 270 到 290 | °C | ||
Front Temperature | 270 到 290 | °C | ||
Back Pressure | 0.200 到 0.300 | Mpa | ||
Screw Speed | 20 到 60 | rpm | ||
Drying Temperature | 80 | °C | ||
Suggested Max Moisture | 0.15 到 0.25 | % | ||
Processing (Melt) Temp | 270 到 295 | °C | ||
Mold Temperature | 85 到 100 | °C |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Unnotched Izod Impact Strength | 23°C | ASTM D4812 | 330 | J/m |
23°C 8 | ISO 180/1U | 23 | kJ/m² |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Glow Wire Flammability Index | 1.0 to 3.0 mm | IEC 60695-2-12 | 960 | °C |
Glow Wire Ignition Temperature | 1.0 mm | IEC 60695-2-13 | 750 | °C |
3.0 mm | IEC 60695-2-13 | 800 | °C | |
Flame Rating | 0.8 mm | UL 94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.