Technical Data Sheet

Physical PropertiesTest ConditionTest MethodTest ResultUnit
Modeling ShrinkageTDISO294-40.40到0.60%
Modeling ShrinkageMDISO294-40.20到0.60%
Modeling ShrinkageMDASTMD9550.20到0.30%
Modeling ShrinkageTDASTMD9550.50到0.70%
Moisture AbsorptionSaturation,23°CISO620.020%
Modeling ShrinkageISO 294-40.2-0.6%
Specific VolumeASTMD7920.611cm³/g
Density / Specific GravityASTMD792,ISO11831.65g/cm³
Mechanical PropertiesTest ConditionTest MethodTest ResultUnit
Flexural StressISO178285Mpa
IZOD Notch Impact StrengthISO 180/1A10kJ/m²
Tensile StrengthBreak,23°CASTMD638200Mpa
Tensile StrengthBreakISO527-2/1A/5195Mpa
Tensile ModulusISO 52714700Mpa
Tensile Modulus-40°CASTMD63814500Mpa
Tensile Modulus75°CASTMD63811900Mpa
Tensile Modulus150°CASTMD6384270Mpa
Tensile Modulus200°CASTMD6383240Mpa
Tensile Modulus--ISO527-2/1A/114700Mpa
Tensile StrengthISO 527195Mpa
Tensile ElongationBreak,23°CASTMD6381.7%
Tensile ElongationBreakISO527-2/1A/51.9%
Rockwell HardnessASTM-D785100R-Scale
Flexural Modulus23°CISO17814500Mpa
Flexural ModulusISO 17814500Mpa
Flexural StrengthISO 178285Mpa
Thermal PropertiesTest ConditionTest MethodTest ResultUnit
Deflection Temperature Under Load?1.80MpaISO 75-A270°C
Deflection Temperature Under Load?0.45MPa,AnnealedASTMD648280°C
Deflection Temperature Under Load?1.8MPa,UnannealedASTMD648265°C
Deflection Temperature Under Load?1.8MPa,UnannealedISO75-2/A270°C
Deflection Temperature Under Load?8.0MPa,UnannealedISO75-2/C215°C
Flame RatingUL94V-0
Linear thermal expansion coefficientMDISO11359-22.6E-05cm/cm/°C
Linear thermal expansion coefficientTDISO11359-24.2E-05cm/cm/°C
Glass Transition TemperatureISO11357-290.0°C
Melting TemperatureISO11357-3280°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Dissipation Factor?1MHzIEC602506.2E-03
Dissipation Factor?1kHzASTMD1501E-03
Dissipation Factor?1MHzASTMD1501E-03
Comparative Tracking IndexIEC60112125V
Dielectric StrengthIEC60243-128KV/mm
Surface ResistivityIEC60093>1.0E+15ohms
Dielectric Constant1kHzASTMD1503.50
Dielectric Constant1MHzASTMD1503.50
Dielectric Constant1MHzIEC602504.60
Arc ResistanceASTMD495134sec
Volume Resistivity--ASTMD2571E+16ohms·cm
Volume Resistivity--IEC60093>1.0E+15ohms·cm
Fill AnalysisTest ConditionTest MethodTest ResultUnit
SpecificHeatCapacityofMelt内部方法1500J/kg/°C
Optical PropertiesTest ConditionTest MethodTest ResultUnit
Filler Content40%
Impact PropertiesTest ConditionTest MethodTest ResultUnit
Charpy Notched Impact Strength-30°CISO179/1eA10kJ/m²
Charpy Notched Impact Strength23°CISO179/1eA10kJ/m²
Notched Izod Impact Strength-30°CISO180/1A10kJ/m²
Notched Izod Impact Strength23°CISO180/1A10kJ/m²
Notched Izod impact strength23°CISO180/1U34kJ/m²
Charpy Unnotched Impact Strength-30°CISO179/1eU53kJ/m²
Charpy Unnotched Impact Strength23°CISO179/1eU53kJ/m²
hardnessTest ConditionTest MethodTest ResultUnit
Rockwell HardnessM-ScaleASTMD785100
Rockwell HardnessM-SaleISO2039-2100
FlammabilityTest ConditionTest MethodTest ResultUnit
UL flame retardant rating0.38mmUL94V-0
UL flame retardant rating1.5mmUL94V-0
UL flame retardant rating3.0mmUL945VA
Oxygen IndexISO4589-247%
PhysicalTest ConditionTest MethodTest ResultUnit
Moisture AbsorptionASTM-D5700.02%
Density / Specific GravityISO 11831.65g/cm³
Supplementary informationTest ConditionTest MethodTest ResultUnit
SpecimenThickness-Shrinkage内部方法3.18mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.