Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | Across Flow : 1.00 mm | 内部方法 | 0.39 | % |
Modeling Shrinkage | 流量 : 1.00 mm | 内部方法 | 0.030 | % |
Moisture Absorption | 24 hr, 23°C | ISO 62 | 0.020 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Elongation | Break | ASTM D638 | 2.8 | % |
Flexural Modulus | | ISO 178 | 11000 | Mpa |
Flexural Stress | | ISO 178 | 160 | Mpa |
Flexural Strain | | ISO 178 | 2.8 | % |
Tensile Strength | | ASTM D638 | 125 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | 0.45 MPa, Unannealed | ISO 75-2/B | 275 | °C |
Deflection Temperature Under Load? | 1.8 MPa, Unannealed | ISO 75-2/A | 250 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Arc Resistance | | ASTM D495 | 151 | sec |
Volume Resistivity | | IEC 60093 | 1.0E+16 | ohms·cm |
Dissipation Factor? | 1 kHz | IEC 60250 | 0.020 | |
Dissipation Factor? | 1 MHz | IEC 60250 | 0.030 | |
Dielectric Strength | 1.00 mm | IEC 60243-1 | 53 | KV/mm |
Dielectric Strength | 3.00 mm | IEC 60243-1 | 26 | KV/mm |
Relative Permittivity | 1 kHz | IEC 60250 | 4.20 | |
Relative Permittivity | 1 MHz | IEC 60250 | 3.70 | |
Comparative Tracking Index | | IEC 60112 | 150 | V |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | M -Sale | ISO 2039-2 | 55 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | | UL 94 | V-0 | |
Color Number | | | VF2201/BK210P | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.