Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 24 hr | ASTM D570 | 0.070 | % |
Density / Specific Gravity | | ASTM D792 | 1.08 | g/cm³ |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Strength | Yield | ASTM D638 | 42.0 | Mpa |
Tensile Elongation | Break | ASTM D638 | 50 | % |
Flexural Modulus | 100 mm Span | ASTM D790 | 2270 | Mpa |
Flexural Strength | Yield, 100 mm Span | ASTM D790 | 67.0 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
RTI | | UL 746 | 50.0 | °C |
RTI Imp | | UL 746 | 50.0 | °C |
RTI Elec | | UL 746 | 50.0 | °C |
Deflection Temperature Under Load? | 0.45 MPa, Unannealed, 6.40 mm | ASTM D648 | 93.0 | °C |
Deflection Temperature Under Load? | 1.8 MPa, Unannealed, 6.40 mm | ASTM D648 | 82.0 | °C |
Coefficient of Linear Thermal Expansion (Flow) | -40 to 95°C | ASTM E831 | 7.4E-5 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Comparative Tracking Index | | UL 746 | PLC 2 | |
Hot-wire Ignition | | UL 746 | PLC 1 | |
High Amp Arc Ignition | | UL 746 | PLC 0 | |
High Voltage Arc Tracking Rate | | UL 746 | PLC 4 | |
Arc Resistance | | ASTM D495 | PLC 7 | |
Dielectric Constant | 60 Hz | ASTM D150 | 2.80 | |
Dielectric Constant | 50 kHz | ASTM D150 | 2.80 | |
Dissipation Factor? | 50 Hz | ASTM D150 | 4.0E-3 | |
Dissipation Factor? | 60 Hz | ASTM D150 | 4.0E-3 | |
Dissipation Factor? | 1 MHz | IEC 60250 | 3.5E-3 | |
Dielectric Strength | 3.20 mm, in Oil | ASTM D149 | 25 | KV/mm |
Extrusion | Test Condition | Test Method | Test Result | Unit |
---|
Drying Temperature | | | 90 到 100 | °C |
Drying Time | | | 2.0 到 4.0 | hr |
Suggested Max Moisture | | | 0.020 | % |
Cylinder Zone 1 Temp | | | 170 | °C |
Cylinder Zone 2 Temp | | | 170 | °C |
Die Temperature | | | 205 | °C |
Cylinder Zone 3 Temp | | | 190 | °C |
Cylinder Zone 4 Temp | | | 190 | °C |
Adapter Temperature | | | 205 | °C |
Melt Temperature | | | 195 到 210 | °C |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Gardner Impact | -40°C | ASTM D3029 | 13.0 | J |
Gardner Impact | -30°C | ASTM D3029 | 24.0 | J |
Notched Izod Impact Strength | -40°C | ASTM D256 | 160 | J/m |
Notched Izod Impact Strength | 23°C | ASTM D256 | 390 | J/m |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | R-Scale | ASTM D785 | 113 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | 1.5 mm | UL 94 | V-1 | |
Flame Rating | 3.0 mm | UL 94 | V-0 | |
Radiant Panel Listing | | UL Unspecified | TRUE | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.