Need Help? Contact Us service@plas.com
Get App

PBT/ASA Ultradur®  S 4090 G2 BK BASF GERMANY

44
  • Unit Price:
    $4230 USD/MT
  • Packaging Specification:
    25KG/PKG
  • Supply Quantity:
    20MT
  • Delivery Terms:
    FOB
  • Port of Loading:
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

serv********

For more detailed information including pricing, customization, and shipping, please contact supplier.

Technical Data Sheet

Physical PropertiesTest ConditionTest MethodTest ResultUnit
Moisture Absorption23°C,24hrISO620.40%
Moisture Absorption23°C,50RHISO620.20%
DensityISO11831.31g/cm³
Melt Mass-Flow Rate275℃/2.16KgISO113335cm3/10min
Mechanical PropertiesTest ConditionTest MethodTest ResultUnit
Charpy Unnotched Impact Strength23°CISO179/1eU37kJ/m²
Charpy Unnotched Impact Strength-30°CISO179/1eU24kJ/m²
Tensile Elongation?(Break)23°CISO527-22.9%
Tensile Modulus23°CISO527-24500Mpa
Tensile Strength23°CISO527-275Mpa
Flexural Strength23°CISO178119Mpa
Charpy Notched Impact Strength23°CISO179/1eA4.0kJ/m²
Tensile Creep Modulus1000HrISO899-13300Mpa
Thermal PropertiesTest ConditionTest MethodTest ResultUnit
Melting temperatureISO11357-3223°C
Coefficient of Linear Thermal ExpansionMDISO11359-25.5E-05cm/cm/°C
Deflection Temperature Under Load?0.45MPa未退火ISO75-2/Bf190°C
Deflection Temperature Under Load?1.80MPa未退火ISO75-2/Af105°C
Thermal ConductivityDIN526120.27W/m/K
Electrical performanceTest ConditionTest MethodTest ResultUnit
Surface resistanceIEC600931E+14Ω.cm
Dielectric Constant23°CIEC602503.60100HZ
Dielectric Constant23°CIEC602503.401MHz
Insulation strength1.50mmIEC60243-122KV/mm
Volume ResistivityIEC600931E+14Ω.cm
Dissipation Factor?23°CIEC602503.1E-03100HZ
Dissipation Factor?23°CIEC602500.0211MHz
Flame retardancyTest ConditionTest MethodTest ResultUnit
Fire ratingAllcolorUL-940.71mmHB
Fire ratingAllcolorUL-941.50mmHB
Fire ratingAllcolorUL-943.00mmHB
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.