PARA IXEF® 1002/0008 SOLVAY USA
192
- Unit Price:
- $7975 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 28MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:Creep resistance high strength Filler: Glass fiber reinf 30% Filler by weight
- Application Areas:Bushing Gear Electrical enclosure Electrical appliances Power/Other Tools Industrial applications Machine/mechanical compon Home appliance components furniture Metal substitution Vehicle electronics Application in the automo Automotive interior parts Automotive External Parts Phone sporting goods Camera applications
- Color:--
- Grade:Coating grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Water absorption rate | 23°C,24hr | ISO62 | 0.20 | % |
Water absorption - Ejil, 65% RH | 内部方法 | 1.9 | % | |
Shrinkage rate | MD | 内部方法 | 0.10到0.40 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile modulus | ISO527-2 | 11500 | Mpa | |
Tensile stress | Break | ISO527-2 | 190 | Mpa |
Tensile strain | Break | ISO527-2 | 2.0 | % |
Bending modulus | ISO178 | 11500 | Mpa | |
Bending stress | ISO178 | 285 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Linear coefficient of thermal expansion | MD | ISO11359-2 | 1.8E-05 | cm/cm/°C |
Hot deformation temperature | 1.8MPa,Unannealed | ISO75-2/A | 230 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Volume resistivity | IEC60093 | 1E+13 | ohms·cm | |
Dielectric strength | IEC60243-1 | 30 | KV/mm | |
Dielectric constant | 110Hz | IEC60250 | 3.90 | |
Dissipation factor | 110Hz | IEC60250 | 0.010 | |
Leakage Trace Index | IEC60112 | 400 | V |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Cantilever beam without notch impact strength | ASTMD256 | 460 | J/m |
flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
UL flame retardant rating 3 | UL94 | HB | ||
Extreme Oxygen Index | ISO4589-2 | 25 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.