PC/PBT XENOY™ 3706 BK1066 SABIC INNOVATIVE US
210
- Unit Price:
- $4247 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 50MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:Impact modification
- Application Areas:Lawn equipment Electrical field Electrical appliances Electronic field Electronic display Architectural application Outdoor applications Garden equipment Lighting applications
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Shrinkage rate | -,flow, 3.2 mm | % | SABIC Method | 1.2 - 1.4 |
-,xflow, 3.2 mm | % | SABIC Method | 1.2 - 1.4 |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
IZOD notch impact strength | 23℃ | cm-kgf/cm | ASTM D256 | 68 |
Tensile modulus | kgf/cm | ASTM D638 | ||
Bending modulus | kgf/cm | ASTM D790 | 20300 | |
bending strength | kgf/cm | ASTM D790 | ||
Tensile strength at break | kgf/cm | ASTM D638 | 400 | |
Yield tensile strength | kgf/cm | ASTM D638 | 490 | |
Fracture tensile strain | % | ASTM D638 | ||
Yield tensile strain | % | ASTM D638 | ||
Instrumented total impact energy | 23℃ | ISO527-2/1 | ASTM D3763 | 506 |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Vicat softening temperature | ℃ | ASTM D1525 | ||
Relative temperature index | -,Elec | ℃ | UL 746B | |
-,Mech w/impact | ℃ | UL 746B | 85 | |
-,Mech w/o impact | ℃ | UL 746B | ||
Melt index | 260°C/5.0 kgf | g/10min | ASTM D1238 | 23 |
Hot deformation temperature | -,0.45 Mpa,Unannealed | ℃ | ASTM D648 | 126 |
-,1.8Mpa,Unannealed | ℃ | ASTM D648 | 85 | |
Coefficient of thermal expansion | -,-40℃to 40℃, flow | 1/℃ | ASTM E 831 | 7.92E-05 |
-,-40℃to 40℃, xflow | 1/℃ | ASTM E 831 | 8.64E-05 |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Arc resistance | PLC Code | ASTM D495 | ||
Comparative tracking index | PLC Code | UL 746A | 2 | |
Hot wire ignition | PLC Code | UL 746A | 2 | |
High voltage arc tracking rate | PLC Code | UL 746A | ||
94V-0 flame retardant rating | mm | UL 94 | 1.49 | |
94-5VA flame retardant rating score | mm | UL 94 | 2.48 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.