Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | TD | ISO294-4 | 0.60 | % |
Modeling Shrinkage | MD | ISO294-4 | 0.20 | % |
Density / Specific Gravity | | ISO1183 | 1.42 | g/cm³ |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Creep Modulus | 1000hr | ISO899-1 | -- | Mpa |
Tensile Stress | Break | ISO527-2 | 180 | Mpa |
Tensile Strain | Break | ISO527-2 | 3.0 | % |
Tensile Modulus | | ISO527-2 | 10000 | Mpa |
Flexural Modulus | | ISO178 | 9000 | Mpa |
Tensile Creep Modulus | 1hr | ISO899-1 | -- | Mpa |
Poisson Ratio | | ISO527 | 0.38 | |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Linear thermal expansion coefficient | TD:导热系数 | ISO11359-2 | 0.35 | W/m/K |
Linear thermal expansion coefficient | MD:-- | ISO11359-2 | 2E-05 | cm/cm/°C |
Linear thermal expansion coefficient | MD:-40to23°C | ISO11359-2 | 2E-05 | cm/cm/°C |
Linear thermal expansion coefficient | TD:-- | ISO11359-2 | 7.2E-05 | cm/cm/°C |
Linear thermal expansion coefficient | TD:-40to23°C | ISO11359-2 | 7.5E-05 | cm/cm/°C |
Deflection Temperature Under Load? | 0.45MPa,Unannealed | ISO75-2/B | 285 | °C |
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ISO75-2/A | 255 | °C |
Melting Temperature | | ISO11357-3 | 300 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Surface Resistivity | | IEC60093 | -- | ohms |
Dielectric Strength | | IEC60243-1 | 43 | KV/mm |
Comparative Tracking Index | | IEC60112 | 600 | V |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Unnotched Impact Strength | 23°C | ISO179/1eU | 75 | kJ/m² |
Charpy Notched Impact Strength | -40°C | ISO179/1eA | 9.0 | kJ/m² |
Charpy Notched Impact Strength | 23°C | ISO179/1eA | 12 | kJ/m² |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
FMVSS Flammability | | FMVSS302 | SE | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.