Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 24hr | ASTMD570 | 0.20 | % |
Colorb-Hunter3 | | ASTME308 | <1.00 | |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Strength | Yield | ASTMD638 | 53.0 | Mpa |
Tensile Strength | Break | ASTMD638 | 26.0 | Mpa |
Tensile Elongation | Yield | ASTMD638 | 5.0 | % |
Tensile Elongation | Break | ASTMD638 | 70 | % |
Flexural Strength | | ASTMD790 | 80.0 | Mpa |
Flexural Modulus | | ASTMD790 | 2150 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | 0.45MPa,Unannealed | ASTMD648 | 74.0 | °C |
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ASTMD648 | 70.0 | °C |
Vicat Softening Temperature | | ASTMD15256 | 83.0 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric Strength | | ASTMD149 | 16 | KV/mm |
Surface Resistivity | | ASTMD257 | 1E+16 | ohms |
Dielectric Constant | 1kHz | ASTMD150 | 2.60 | |
Dielectric Constant | 1MHz | ASTMD150 | 2.40 | |
Volume Resistivity | | ASTMD257 | 1E+15 | ohms·cm |
Dissipation Factor? | 1kHz | ASTMD150 | 5E-03 | |
Dissipation Factor? | 1MHz | ASTMD150 | 0.023 | |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | R-Scale | ASTMD785 | 116 | |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|
Haze | | ASTMD1003 | <1.0 | % |
Transmittance | | ASTMD1003 | 89.0 | % |
Refractive index of light | | ASTMD542 | 1.570 | |
Gloss | 60° | ASTME308 | 159 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 1.0mm | UL94 | HB | |
UL flame retardant rating | 1.5mm | UL94 | HB | |
UL flame retardant rating | 3.0mm | UL94 | V-2 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.