Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | TD | ISO294-4 | 0.75 | % |
Modeling Shrinkage | MD | ISO294-4 | 0.65 | % |
Moisture Absorption | Saturation,23°C | ISO62 | 1.3 | % |
Moisture Absorption | Equilibrium,23°C,50%RH | ISO62 | 0.60 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Stress | Yield | ISO527-2 | 47.0 | Mpa |
Tensile Strain | Yield | ISO527-2 | 5.0 | % |
Tensile Strain | Break | ISO527-2 | >50 | % |
Tensile Modulus | | ISO527-2 | 1800 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | 0.45MPa,Unannealed | ISO75-2/B | 140 | °C |
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ISO75-2/A | 50.0 | °C |
Vicat Softening Temperature | -- | ISO306/A | 175 | °C |
Vicat Softening Temperature | -- | ISO306/B | 150 | °C |
Melting Temperature | | ISO11357-3 | 178 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Relative Permittivity | 23°C,1MHz | IEC60250 | 3.60 | |
Comparative Tracking Index | -- | IEC60112 | 600 | V |
Comparative Tracking Index | SolutionA3 | IEC60112 | >600 | V |
Dissipation Factor? | 23°C,1MHz | IEC60250 | 0.034 | |
Dielectric Strength | | IEC60243-1 | 28 | KV/mm |
Volume Resistivity | | IEC60093 | 1E+14 | ohms·cm |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Unnotched Impact Strength | -30°C,Complete Break | ISO179/1eU | 80 | kJ/m² |
Charpy Unnotched Impact Strength | 23°C,Complete Break | ISO179/1eU | 65 | kJ/m² |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 1.6mm | UL94 | V-0 | |
UL flame retardant rating | 3.2mm | UL94 | V-0 | |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|
ISO Shortname | | ISO1874 | PA12,KFH,12-020 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.