PPO NORYL™ HS2000X-111 SABIC INNOVATIVE SHANGHAI
137
- Unit Price:
- $6592 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 10MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:Glass fiber mineral reinf Dimensional stability Low water absorption
- Application Areas:Electronic and Electrical Air conditioning accessor Indoor applications Outdoor applications Water pump accessories Shell Smoke detector cover Swimming Pool Facilities
- Color:--
- Grade:--
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Shrinkage rate | MD:3.20mm | 内部方法 | 0.50到0.70 | % |
Melt mass flow rate | 280°C/5.0kg | ASTMD1238 | 7.6 | g/10min |
300°C/5.0kg | ASTMD1238 | 7.6 | g/10min | |
Melt volume flow rate | 280°C/5.0kg | ISO1133 | 6.80 | cm3/10min |
300°C/5.0kg | ISO1133 | 6.80 | cm3/10min | |
Outdoor applicability | UL746C | f1 |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Surrender 2 | ASTMD638 | 74.0 | Mpa | |
Fracture 3 | ASTMD638 | 60.0 | Mpa | |
yield | ISO527-2 | 71.7 | Mpa | |
ASTMD638 | 3.8 | % | ||
ISO527-2 | 3.7 | % | ||
crack | ISO527-2 | 57.1 | Mpa | |
ISO527-2 | 11 | % | ||
50.0mm span 6 | ASTMD790 | 3670 | Mpa | |
--1 | ASTMD638 | 3650 | Mpa | |
Yield, 100mm span 7 | ASTMD790 | 117 | Mpa | |
Fracture, 50.0mm span 8 | ASTMD790 | 117 | Mpa | |
Fracture 4 | ASTMD638 | 8.4 | % | |
100mm span 5 | ASTMD790 | 3550 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
1.8MPa, unannealed, 6.40mm | ASTMD648 | 116 | °C | |
0.45MPa, unannealed, 6.40mm | ASTMD648 | 128 | °C | |
0.45MPa, unannealed, 100mm span of 10 | ISO75-2/Be | 126 | °C | |
RTI | UL746 | 100 | °C | |
RTIElec | UL746 | 100 | °C | |
Evolution Calendar intelligent importer | UL746 | 85.0 | °C | |
1.8MPa, unannealed, 3.20mm | ASTMD648 | 108 | °C | |
0.45MPa, unannealed, 3.20mm | ASTMD648 | 117 | °C | |
1.8MPa, unannealed, 100mm span 11 | ISO75-2/Ae | 111 | °C | |
-- | ISO306/B50 | 132 | °C | |
ISO306/B120 | 136 | °C | ||
Linear coefficient of thermal expansion | MD:-40to40°C | ASTME831 | 7.1E-05 | cm/cm/°C |
TD:-40to40°C | ASTME831 | 7.8E-05 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Dielectric strength | 3.20mm,inOil | ASTMD149 | 17 | KV/mm |
Compared to the anti leakage trace index | CTI | UL746 | PLC2 | |
Hot wire ignition | HWI | UL746 | PLC0 | |
High arc combustion index | HAI | UL746 | PLC2 | |
High voltage arc tracing rate | HVTR | UL746 | PLC3 | |
Dissipation factor | 1MHz | ASTMD150 | 4.4E-03 | |
50Hz | ASTMD150 | 0.017 | ||
60Hz | ASTMD150 | 0.017 | ||
Surface resistivity | ASTMD257 | >1.0E+16 | ohms | |
Dielectric constant | 50Hz | ASTMD150 | 2.89 | |
60Hz | ASTMD150 | 2.89 | ||
1MHz | ASTMD150 | 2.70 | ||
Volume resistivity | ASTMD257 | 1.2E+16 | ohms·cm | |
Arc resistance 12 | ASTMD495 | PLC6 |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
23°C | ASTMD256 | 130 | J/m | |
Dart impact equipped with measuring instruments | 23°C,TotalEnergy | ASTMD3763 | 443 | J |
Reverse notch impact | 3.20mm | ASTMD256 | 810 | J/m |
23°C9 | ISO180/1A | 9.7 | kJ/m² | |
Cantilever beam without notch impact strength | 23°C | ASTMD4812 | 2200 | J/m |
flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
UL flame retardant rating | 1.47mm | UL94 | V-0 | |
2.01mm | UL94 | 5VA | ||
RadiantPanelListing(UL) | UL94 | YES |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.