Technical Data Sheet
Compare
Physical properties | Test Condition | Test Method | Test Result | Unit |
---|
density | | ASTM D792/ISO 1183 | 1.2 | |
Water absorption rate 23 ℃/24h | | ASTM D570/ISO 62 | 0.2 | % |
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Light transmittance | 厚度3mm | ASTM D-1003 | 88 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Impact strength value | 艾氏、带Notched厚度3.2mm | ASTM D-256 | 830(85) | j/m(kgf.cm/cm) |
Impact strength value | 艾氏、带Notched厚度6.4mm | ASTM D-256 | 130(13) | j/m(kgf.cm/cm) |
Stretching rate | Yield点,- | ASTM D-638 | 6 | - |
Stretching rate | Break点,- | ASTM D-638 | 140 | - |
compressive strength | | ASTM D-695 | 76(780) | MPa(Kgf/cm |
Tensile modulus | | ASTM D638/ISO 527 | 2130 | kg/cm²(MPa)[Lb/in²] |
Tensile modulus | | ASTM D-638 | 2130(21700) | MPa(Kgf/cm |
tensile strength | Yield点,- | ASTM D-638 | 62(630) | MPa(Kgf/cm |
tensile strength | Break点,- | ASTM D-638 | 78(800) | MPa(Kgf/cm |
elongation | | ASTM D638/ISO 527 | 6 | % |
Rockwell hardness | | ASTM D785 | 77 | |
Rockwell hardness | | ASTM D-785 | 77 | M标度 |
Bending modulus | | ASTM D-790 | 2260(23000) | MPa(Kgf/cm |
bending strength | | ASTM D790/ISO 178 | 90 | kg/cm²(MPa)[Lb/in²] |
bending strength | | ASTM D-790 | 90(920) | MPa(Kgf/cm |
Refractive index | | ASTM D-542 | 1.585 | |
Tensile elongation at break (elongation at break) | | ASTM D638/ISO 527 | 140 | % |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Linear expansion coefficient | | ASTM D696/ISO 11359 | 7 | mm/mm.℃ |
Temperature index | 电学式,厚度1.47mm | UL 746B | 125 | °C |
Temperature index | 冲击式,厚度1.47mm | UL 746B | 115 | °C |
Temperature index | 非冲击式,厚度1.47mm | UL 746B | 125 | °C |
Load deflection temperature | 负荷1.813MPa(18.6kgf/cm) | ASTM D-648 | 132 | °C |
Load deflection temperature | 负荷0.451MPa(4.6kgf/cm) | ASTM D-648 | 142 | °C |
Coefficient of linear expansion | Flow (Across Flow ) | ASTM D-696 | 7 | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric tangent | 60Hz(10 | ASTM D-150 | 0.0004(0.009) | |
Conductive Track Resistance (CTI) | | IEC 112 | 300 | V |
Dielectric constant | 60Hz(10 | ASTM D-150 | 2.95(2.9) | |
Insulation breakdown strength | 快速加压值厚度1.6mm | ASTM D-149 | 30 | KV/mm |
Arc resistance | | ASTM D-495 | 110 | sec |
Arc resistance | | ASTM D495/IEC 60112 | 110 | |
Volume resistivity | | ASTM D-257 | 3 | |
Processing performance | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | Flow ,- | ASTM D-955 | 0.5~0.7 | % |
Shrinkage rate | Across Flow ,- | ASTM D-955 | 0.5~0.7 | % |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|
Light transmittance | | ASTM D1003/ISO 13468 | 88 | % |
Basic performance | Test Condition | Test Method | Test Result | Unit |
---|
Water absorption rate | 24hr,in 23℃ | ASTM D-570 | 0.20 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.