Technical Data Sheet
Compare
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Melt flow rate | 230°C/3.8 kg | ISO 1133 | 2.8 | g/10 min |
Shrinkage rate - flow | | ASTM D955 | 0.20 到 0.60 | % |
Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 0.30 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile stress | Yield, 23°C | ISO 527-2 | 70.0 | Mpa |
Tensile strain | Break, 23°C | ISO 527-2 | 6.0 | % |
Bending modulus | 23°C | ISO 178 | 3300 | Mpa |
Bending stress | 23°C | ISO 178 | 103 | Mpa |
Compressive stress | 23°C | ISO 604 | 117 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 103 | °C |
Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 100 | °C |
Vicat softening temperature | | ISO 306/B | 108 | °C |
Linear coefficient of thermal expansion - flow | -30 to 23°C | ASTM D696 | 6.5E-5 | cm/cm/°C |
specific heat | | | 2090 | J/kg/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Surface resistivity | | ASTM D257 | > 1.0E+14 | ohms |
Volume resistivity | | ASTM D257 | > 1.0E+15 | ohms·cm |
Dielectric strength | | ASTM D149 | 20 | KV/mm |
Dielectric constant | 60 Hz | ASTM D150 | 3.70 | |
Dissipation factor | 1 MHz | ASTM D150 | 0.040 | |
injection | Test Condition | Test Method | Test Result | Unit |
---|
drying temperature | | | 85 到 90 | °C |
drying time | | | 2.0 到 4.0 | hr |
Processing (melt) temperature | | | 230 到 250 | °C |
Mold temperature | | | 80 到 90 | °C |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Impact strength of simply supported beam without notch | 23°C | ISO 179/2U | 11 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell hardness | M-Scale | ASTM D785 | 97 | |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|
Refractive index 3 | | ISO 489 | 1.490 | |
transmissivity | | ASTM D1003 | 92.0 | % |
Haze | | ASTM D1003 | 0.50 | % |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | | UL 94 | HB | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.