Technical Data Sheet
Compare
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | TD:23°C | ISO294-4 | 1.6 | % |
Shrinkage rate | MD:23°C | ISO294-4 | 1.5 | % |
Water absorption rate | 23°C,24hr | ISO62 | 1.4 | % |
Water absorption rate | Saturation,23°C | ISO62 | 6.0 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile stress | Yield,23°C | ISO527-2 | 85.0 | Mpa |
Tensile strain | Break,23°C | ISO527-2 | 8.0 | % |
Tensile modulus | 23°C | ISO527-2 | 3400 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Hot deformation temperature | 0.45MPa,Unannealed | ISO75-2/B | 185 | °C |
Hot deformation temperature | 1.8MPa,Unannealed | ISO75-2/A | 85.0 | °C |
Continuous use temperature 2 | | IEC60216 | 130 | °C |
BallPressure Test | 125°C | IEC60695-10-2 | Pass | |
BallPressure Test | 165°C | IEC60695-10-2 | Pass | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Surface resistivity 3 | | IEC60093 | 1E+13 | ohms |
Volume resistivity | 23°C | IEC60093 | 1E+15 | ohms·cm |
Dielectric strength | 2.00mm | IEC60243-1 | 25 | KV/mm |
Compared to the anti leakage trace index | 3.20mm,SolutionA | IEC60112 | 600 | V |
Needle flame test | 1.00mm | IEC60695-11-5 | Pass | |
Needle flame test | 2.00mm | IEC60695-11-5 | Pass | |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Impact strength of simply supported beam without notch | -30°C | ISO179/1eU | NoBreak | |
Impact strength of simply supported beam without notch | 23°C | ISO179/1eU | NoBreak | |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 0.8mm | UL94 | V-0 | |
UL flame retardant rating | 1.6mm | UL94 | V-0 | |
UL flame retardant rating | 3.2mm | UL94 | V-0 | |
UL flame retardant rating | 0.40mm | UL94 | V-0 | |
Burning wire flammability index | 0.8mm | IEC60695-2-12 | 960 | °C |
Burning wire flammability index | 3.2mm | IEC60695-2-12 | 960 | °C |
Extreme Oxygen Index | | ISO4589-2 | 33 | % |
Hot filament ignition temperature | 0.8mm | IEC60695-2-13 | 775 | °C |
Hot filament ignition temperature | 3.2mm | IEC60695-2-13 | 775 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.