PA66 A 246 M SOLVAY KOREA
107
- Unit Price:
- $3489 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 40.6MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:--
- Application Areas:Application in the automo sporting goods
- Color:--
- Grade:Toughened grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Water absorption rate | 23°C,24hr | ISO62 | 1.1 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile stress | Yield,23°C | ISO527-2/1A | 47.0 | Mpa |
Break,23°C | ISO527-2/1A | 44.0 | Mpa | |
Tensile strain | Yield,23°C | ISO527-2 | 20 | % |
Bending stress | 23°C | ISO178 | 70.0 | Mpa |
Tensile modulus | 23°C | ISO527-2/1A | 1900 | Mpa |
elongation | Break,23°C | ASTMD638 | 80 | % |
Bending modulus | 23°C | ASTMD790 | 1800 | Mpa |
23°C | ISO178 | 1800 | Mpa | |
bending strength | 23°C | ASTMD790 | 70.0 | Mpa |
Tensile strength | Yield,23°C | ASTMD638 | 50.0 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Melting temperature | ISO11357-3 | 263 | °C | |
Hot deformation temperature | 0.45MPa,Unannealed | ASTMD648 | 200 | °C |
1.8MPa,Unannealed | ASTMD648 | 63.0 | °C | |
1.8MPa,Unannealed | ISO75-2/Af | 65.0 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Surface resistivity | IEC60093 | 1E+15 | ohms | |
Volume resistivity | IEC60093 | 1E+15 | ohms·cm | |
Dielectric strength | 2.00mm | IEC60243-1 | 30 | KV/mm |
Relative permittivity | IEC60250 | 3.20 | ||
Leakage Trace Index | SolutionA | IEC60112 | 575 | V |
SolutionB | IEC60112 | 450 | V | |
Dissipation factor | IEC60250 | 0.020 |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Impact strength of simply supported beam without notch | -30°C | ISO179/1eU | 16 | kJ/m² |
23°C | ISO179/1eU | NoBreak |
flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
FlameRating | 1.6mm | UL94 | HB | |
Extreme Oxygen Index | ISO4589-2 | 25 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.