Technical Data Sheet
Compare
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | Across Flow | ISO 294-4 | 0.90 | % |
Shrinkage rate | 流量 | ISO 294-4 | 0.10 | % |
Water absorption rate | Saturation, 23°C | ISO 62 | 5.0 | % |
Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 2.0 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile modulus | | ISO 527-2 | 11000 | Mpa |
Tensile stress | Break | ISO 527-2 | 200 | Mpa |
Tensile strain | Break | ISO 527-2 | 2.5 | % |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 285 | °C |
Hot deformation temperature | 8.0 MPa, Unannealed | ISO 75-2/C | 200 | °C |
Continuous use temperature | -- 2 | ISO 2578 | 140 | °C |
Continuous use temperature | -- 3 | 内部方法 | 260 | °C |
Melting temperature 4 | | ISO 11357-3 | 310 | °C |
Linear coefficient of thermal expansion | Flow | ISO 11359-2 | 2.0E-5 | cm/cm/°C |
Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 6.0E-5 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Surface resistivity | | IEC 60093 | -- | ohms |
Volume resistivity | | IEC 60093 | 1.0E+12 | ohms·cm |
Dielectric strength | | IEC 60243-1 | 38 | KV/mm |
Leakage Trace Index | | IEC 60112 | -- | V |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 50 | kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 55 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Ball pressure hardness | | ISO 2039-1 | 260 | Mpa |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
Flammability level | 0.8 mm | IEC 60695-11-10, -20 | HB | |
ISO Type | | ISO 1874 | PA 6T/66, MH, 14-110, GF33 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.