UHMWPE GUR®  GHR 8110 CELANESE USA

223
  • Unit Price:
    $2985 USD/MT
  • Packaging Specification:
    25 KG/PKG
  • Supply Quantity:
    119.1MT
  • Delivery Terms:
    FOB
  • Port of Loading:
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 2787 3515View
serv********View

For more detailed information including pricing, customization, and shipping, please contact supplier.

Material Description
Technical Data Sheet

Material Description

  • Material Properties:wear resistant High impact resistance
  • Application Areas:Automotive Applications transportation industry
  • Color:--
  • Grade:Wear resistant grade

Technical Data Sheet Compare

physical property Test ConditionTest MethodTest ResultUnit
Melt mass flow rate190°C/21.6kgASTMD12381.4g/10min
Melt mass flow rate190°C/2.16kgISO11331.3g/10min
Stickiness numberISO307600cm³/g
Intrinsic viscosityISO1628-36.0dl/g
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile strainYieldISO527-2/1A/509.0%
Nominal tensile fracture strainISO527-2/1A/50>50%
Tensile creep modulus1hrISO899-1680Mpa
Tensile creep modulus1000hrISO899-1340Mpa
WearbySandslurryMethod3内部方法310
Wear amount内部方法250
Tensile modulusISO527-2/1A/11100Mpa
Tensile stressYieldISO527-2/1A/5026.0Mpa
Thermal performanceTest ConditionTest MethodTest ResultUnit
Linear coefficient of thermal expansionMDASTMD696,ISO11359-22E-04cm/cm/°C
specific heat23°C内部方法1840J/kg/°C
thermal conductivity23°C内部方法0.41W/m/K
Hot deformation temperature0.45MPa,UnannealedISO75-2/B75.0°C
Hot deformation temperature1.8MPa,UnannealedISO75-2/A41.0°C
Vicat softening temperatureASTMD1525,ISO306/B5080.0°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Surface resistivity--ASTMD257>1.0E+13ohms
Surface resistivity--IEC60093>1.0E+12ohms
Volume resistivity--ASTMD257>1.0E+15ohms·cm
Volume resistivity--IEC60093>1.0E+14ohms·cm
Dielectric strengthIEC60243-140KV/mm
Dielectric constant1MHzASTMD1502.90
Dielectric constant100HzIEC602502.00
Dielectric constant1MHzIEC602502.00
Dissipation factor100HzIEC602502E-04
Dissipation factor1MHzIEC602504E-04
Leakage Trace IndexIEC60112600V
Impact performanceTest ConditionTest MethodTest ResultUnit
CharpyImpactStrength4ISO1152-225.0kJ/m²
hardnessTest ConditionTest MethodTest ResultUnit
Shore hardnessShore DASTMD224063
Shore hardnessShore D,15secISO86863
flammabilityTest ConditionTest MethodTest ResultUnit
UL flame retardant rating1.6mmUL94HB
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.