physical property | Test Condition | Test Method | Test Result | Unit |
---|
Apparent density | | ISO60 | 0.80 | g/cm³ |
Melt volume flow rate | 260°C/5.0kg | ISO1133 | 30.0 | cm3/10min |
Shrinkage rate | TD:270°C,2.00mm2 | ISO294-4 | 0.90 | % |
Shrinkage rate | TD:120°C,2hr,2.00mm3 | ISO294-4 | 0.20 | % |
Shrinkage rate | MD:270°C,2.00mm2 | ISO294-4 | 0.30 | % |
Shrinkage rate | MD:120°C,2hr,2.00mm3 | ISO294-4 | 0.10 | % |
Water absorption rate | Saturation,23°C | ISO62 | 0.30 | % |
Water absorption rate | Equilibrium,23°C,50%RH | ISO62 | 0.10 | % |
Viscosity value | 降低的粘度 | ISO1628 | 91.0 | ml/g |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile modulus | 23°C | ASTMD638 | 9980 | Mpa |
Tensile modulus | 23°C | ISO527-2/1 | 10400 | Mpa |
Tensile strength | Break,23°C | ASTMD638 | 123 | Mpa |
Tensile stress | Break,23°C | ISO527-2/5 | 145 | Mpa |
elongation | Break,23°C | ASTMD638 | 2.5 | % |
Tensile strain | Break,23°C | ISO527-2/5 | 2.8 | % |
TensileCreepModule | 1hr | ISO899-1 | 10000 | Mpa |
Tensile creep modulus | 1000hr | ISO899-1 | 8500 | Mpa |
Bending modulus | 23°C | ASTMD790 | 8550 | Mpa |
Bending modulus 4 | 23°C | ISO178/A | 10300 | Mpa |
bending strength | 23°C | ASTMD790 | 207 | Mpa |
Bending stress 4 | 23°C | ISO178 | 230 | Mpa |
Bending strain 5 | 23°C | | 3.0 | % |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
TemperatureIndex11 | 介电强度 | IEC60216 | 155 | |
TemperatureIndex11 | 拉伸冲击强度 | IEC60216 | 140 | |
TemperatureIndex11 | 抗张强度 | IEC60216 | 155 | |
Melting temperature 7 | | ISO11357-3 | 225to250 | °C |
Linear coefficient of thermal expansion | MD:23to55°C | ISO11359-2 | 3E-05 | cm/cm/°C |
Linear coefficient of thermal expansion | TD:23to55°C | ISO11359-2 | 6E-05 | cm/cm/°C |
thermal conductivity | 23°C | ISO8302 | 0.27 | W/m/K |
RTIElec | | UL746 | 140 | °C |
Evolution Calendar intelligent importer | | UL746 | 125 | °C |
RTIStr | | UL746 | 140 | °C |
Half Interval | --8 | IEC60216 | 13.5 | °C |
Half Interval | --9 | IEC60216 | 10.2 | °C |
Half Interval | --10 | IEC60216 | 10.2 | °C |
Hot deformation temperature | 0.45MPa,Unannealed | ISO75-2/B | 220 | °C |
Hot deformation temperature | 1.8MPa,Unannealed | ISO75-2/A | 200 | °C |
Vicat softening temperature | | ISO306/B120 | 205 | °C |
BallPressure Test | 220°C | IEC60695-10-2 | Pass | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric strength | 23°C,1.00mm | IEC60243-1 | 27 | KV/mm |
Relative permittivity | 23°C,100Hz | IEC60250 | 4.00 | |
Relative permittivity | 23°C,1MHz | IEC60250 | 3.80 | |
Leakage Trace Index | SolutionA | IEC60112 | 250 | V |
film | Test Condition | Test Method | Test Result | Unit |
---|
FilmPunctureEnergy6 | | ISO6603-2 | 2.10 | J |
Membrane piercing force 6 | | ISO6603-2 | 650 | N |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Impact strength of simply supported beam without notch | -30°C | ISO179/1eU | 55 | kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO179/1eU | 65 | kJ/m² |
Unscented Izod impact strength | -30°C | ISO180/1U | 55 | kJ/m² |
Unscented Izod impact strength | 23°C | ISO180/1U | 55 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Ball pressure hardness | | ISO2039-1 | 200 | Mpa |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 0.8mm | UL94 | HB | |
UL flame retardant rating | 1.6mm | UL94 | HB | |
Burning wire flammability index | 2.0mm | IEC60695-2-12 | 750 | °C |
Extreme Oxygen Index 12 | | ISO4589-2 | 21 | % |
Supplementary Information | Test Condition | Test Method | Test Result | Unit |
---|
ElectrolyticalCorrosion | | IEC60426 | A1 | |
ISO Shortcut | | ISO7792 | PBT+PET,GHLMR,09-100,GF30 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.