physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | TD | ISO294-4 | 2.1 | % |
Shrinkage rate | MD | ISO294-4 | 2.2 | % |
Melt mass flow rate | 240°C/10.0kg | ISO1133 | 10 | g/10min |
Melt volume flow rate | 240°C/10.0kg | ISO1133 | 10.0 | cm3/10min |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile modulus | | ISO527-2 | 190 | Mpa |
Nominal tensile fracture strain | | ISO527-2 | 380 | % |
Tensile stress | Break | ISO527-2 | 35.0 | Mpa |
Tensile stress | 5.0%Strain | ISO527-2 | 7.80 | Mpa |
Tensile stress | 10%Strain | ISO527-2 | 11.9 | Mpa |
Tensile stress | 50%Strain | ISO527-2 | 19.0 | Mpa |
Tensile strain | Break | ISO527-2 | >300 | % |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Melting temperature 2 | | ISO11357-3 | 211 | °C |
Brittle temperature | | ISO974 | -54.0 | °C |
elastomer | Test Condition | Test Method | Test Result | Unit |
---|
Tear strength flow rate | | ISO34-1 | 140 | kN/m |
Filling analysis | Test Condition | Test Method | Test Result | Unit |
---|
ThermalConductivityofMelt | | | 0.16 | W/m/K |
SpecificHeatCapacity of Melt | | | 2150 | J/kg/°C |
Melt density | | | 1.01 | g/cm³ |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile impact strength | 23°C | ISO8256/1 | 330 | kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO179/1eU | 无断裂 | |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Shore hardness | Shore D | ISO868 | 58 | |
Shore hardness | Shore D,15sec | ISO868 | 52 | |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
Burning rate 3 | 1.00mm | ISO3795 | 42 | mm/min |
Supplementary Information | Test Condition | Test Method | Test Result | Unit |
---|
Odor | | VDA270 | 3.50 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.