PETG Eastar™ CM155 EASTMAN USA
146
- Unit Price:
- $2359 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 170MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:High transparency High toughness 28% and 25% fiber grade
- Application Areas:packing sporting goods
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Rockwell hardness | 测试温度74℉,ASTM D785 | 75 | 85 |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
elongation | 测试温度74℉,ASTM D638 | 40 | 35 | % |
Izod impact strength (without fracture) ft lb./in | 测试温度-40℉,ASTM D256 | 1.1 | ||
测试温度73.4℉,ASTM D256 | 3.5 | |||
Tensile strength at break | 测试温度73.4℉,ASTM D638 | 6300 | psi | |
测试温度158℉,ASTM D638 | 3200 | psi | ||
Yield tensile strength | 测试温度73.4℉,ASTM D638 | 4800 | psi | |
Yield bending strength | 测试温度73.4℉,ASTM D790 | 7500 | psi | |
Yield modulus of elasticity | 测试温度73.4℉,ASTM D790 | 1.90 | psi x 105 | |
Load Deformation Rate (Dry) (Cold Flow Method A) - Load 2000psi | 测试温度122℉,ASTM D621 | 3 | % | |
Load Deformation Rate (Dry) (Cold Flow Method A) - Load 1000psi | 测试温度122℉,ASTM D621 | 1 | 1 | % |
Water absorption rate (soaking for 24 hours) - total amount | 测试温度73.4℉,ASTM D570 | 2.3 | % | |
Water absorption rate (soaking for 24 hours) - loss of soluble substances | 测试温度73.4℉,ASTM D570 | 0.2 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.